Laserfiche WebLink
23. Tamper- Resistant.Receptacles in accordance with 406.41 of the 2016!IN.E.0 <br /> 24, In accordance with the Land Development Code,lots shall be sodded before final at-least 10 <br /> feet-around the structure. <br /> 25. R403.5.3Hot Water pipe insulation. <br /> -Ins.ulatiorl for hot water pipe with a minimum thermal resistance(R.value) of R-3 shall be applied to the <br /> following: <br /> Piping 3/; inch (19.1 mm)and larger in nominal diameter.; <br /> Piping.serving more than one dwelling unit: <br /> Piping located outside the conditioned space. <br /> Piping from the:water heater to::a distribution manifold.. <br /> Piping:located under.a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems: <br /> 25. Blower door test shall be provided before CO. <br /> 26. A copy of the enerzy cacls shall be with permit at all times. <br /> 27 Copy of rinal.insulation report shall be provided with permit before fnaA <br /> 28. No fence, 06ol or screen enclosure :is issued with:this permit. <br /> RRE:-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-.Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br /> i <br /> i <br />