Laserfiche WebLink
ED <br /> 4 <br /> f , <br /> I <br /> Single .Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E; shall be a minimum of 8"above the road elevation and an engineered site plan. <br /> 2: Lots shaltbe graded to comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24"or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require a R.O.W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6. All setbacks shall be met. <br /> 7: All property markers shall be uncovered and marked_ at time of first inspection. <br /> 8: All A.D.A. requirements shall be met: <br /> 9. No electric,plumbing.mechanical, or framing shall be:covered without an inspection and <br /> approval first: <br /> 10: All Garages shall comply with section R302.6 of the F.B.-C. (Fire Separation). <br /> 1.1. Appliances shall not be installed in a location where subject.to mechanical:damage unless <br /> protected by approved barriers. M303:4 of the F&C <br /> 12. water heaters shall comply with section P607.3 of the F.B.C. <br /> 13. Foundation supports for AC units.shall be raised at least 3" above finished grade: M1308:1 <br /> 14. Return air in all bedrooms. F.B.C. M1620A <br /> 15. Smoke detectors are to be installed in accordance with.R313.l'of the F.B.C. <br /> 16:All glazing requirements are to be in accordance with R308.4 of the F:B:C: <br /> 17. All means of egress are to be in accordance with R311 of the F.B.C. ! <br /> 18. "Green gypsum board" shall riot be used as a backer-in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are.required at all locations requiring an AM.type breaker. <br /> 20. Carbon nionokide alarms will be required in new construction that uses fossil-burning heating. <br /> or appliances or an attached.garage. They shall be installed in accordance with theRB.C; <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This include_ s all <br /> underground plumbing and electric. <br /> 22. All 2016 N.E.C. Codes will be enforced. <br />