Laserfiche WebLink
r o <br /> I <br /> Snow Load 0-20 psf. <br /> Modules in Landscape <br /> -Wind Speed Exposure 2:12<Roof Pitch<.6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 Zone 3 Zone,1 Zone 2'. Zone'3 <br /> B 159 93 59 <br /> 85 mph 110 mph C 114 67 42 88 88 <br /> D 96 56 35 '91 74 74 <br /> B 146, 85 54 <br /> 90 mph 115 mph C 104 61 38 98 80 80 <br /> D 88 51 32 83 68 68 <br /> B 123 72 45 95 95 <br /> 100 mph 125 mph C 88 51 32 . 83' . '68 68 <br /> D 74 43 27 70 , . 57 .57 <br /> B 98' 57 36 93 76 76 <br /> 110 mph 140 mph C 70 41 26 66 54 54 <br /> D 59' 34 22 56 46 46. <br /> B .85 .50 31. . 81 66 66 <br /> 120 mph 150 mph C 61 36 22.: 58' 47 47 <br /> D 51 30 19 49 40 40 <br /> Notes: <br /> Spacing Governed by Snow Load <br /> 1.)Values in above table.represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff, <br /> however the designer must round down to meet-appropriate rafter spacing <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar Is 72" <br /> 3.)Maximum allowed standoff capcity=547#(per testing results) <br /> 4.)Includes additional factor of safety.of 1:5 for lag pullout capacity <br /> 5.)Values based on a maximum module width of 40" <br /> 6.)Based on Risk Category 11(ASCE 7-10)structures less than 30 feet In height <br /> 7.)Al adjustment-factors are set to 1.No site specific engineering is included in this table <br /> Snow Load 0-20 psf <br /> i <br /> Wind Speed Exposure 2:12<Roof Pitch.<6:12 7:12<Roof Pitch<12:12 <br /> ASCE 7-05 ASCE 7-10 Category Zone 1 Zone 2 _ Zone 3 Zone.1 Zone 2 Zone 3 <br /> B 91 <br /> 85 mph 110 mph C 65 38 24 61 50 1 - 450 _ ) <br /> D 55 _ _ 32 20 w52: _s42;. 2 <br /> B 83 49 30 <br /> 90-mph 115 mph C 59 35 22 56 46 46 <br /> D 50 29 18 47 38 38 <br /> - - - — r---- • WV:, <br /> • B , - - - 70—� _ 41 5.4 <br /> 100 mph 125 mph C 50 29 18 47 39 39R <br /> D 42 _ _ 26 J _15 _ y _40 32 32LL__+ <br /> B 56 33 20 53 43 43 <br /> 110 mph 140 mph C 40 23 14 38 31 31 <br /> D 34 19 12 32 26 26 <br /> 28 - 18 — ~_ 46 ,---37—"- <br /> 120 mph 150 mph C 35 20 12 33 27 27 <br /> D 29- 17 10 28 22 22 <br /> Notes: <br /> -Spacing Governed by Snow Load <br /> 1.)Values in above table represent the maximum allowable spacing in inches for pullout forces only on EcoFasten Solar standoff <br /> 2.)Maximum allowed spacing approved by EcoFasten Solar is 48" <br /> 3.)Maximum allowed.standoff capcity=547#(per testing results) <br /> 4.)Includes.additional factor of safety of 1.5 for lag pullout capacity <br /> 5.)Values based on a maximum module length of 70" <br /> 6.)Based on Risk Category II(ASCE 7-10)structures less than 30 feet in height <br /> 7.)All adjustment factors are set to 1..No site specific engineering Is Included in this table <br /> www.ecofastensolar.com info@ecofastensolarcom 877-859-3947 8 <br />