My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22533
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22533
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 1:41:23 PM
Creation date
5/12/2021 1:47:44 PM
Metadata
Fields
Template:
Building Department
Company Name
CRESTVIEW HILLS
Building Department - Doc Type
Permit
Permit #
20-22533
Building Department - Name
EUGENE,MANLEY & LAFIA
Address
7638 MERCHANTVILLE CIR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
GODWIN ENGINEERING AND DESIGN, LLC <br /> 8378 Foxtail Loop, Pensacola, FL 32526 1 (850)712-4219 chad0godwinerig.com <br /> January 29, 2020 <br /> To: Zephyrhills Building Department <br /> 5335 8th St. <br /> Zephyrhills, FL 33542 <br /> Re: Eugene-Residential PV Roof Mount Installation <br /> 7638 Merchantville Cir. <br /> Zephyrhills, FL 33540 <br /> Plan Reviewer, <br /> This letter is regarding the installation of a new roof mounted Solar PV System on the existing <br /> residential structure at the address above. I have reviewed the attachment plan and have <br /> determined that the roof mounted PV system is in compliance with the applicable sections of the <br /> following Codes as amended and adopted by the jurisdiction: <br /> 2017 Florida Building Code 6tn Edition, FBC <br /> ASCE 7 Min. Design Loads for Buildings&Other Structures <br /> Per 2017 FBC,the Roof Mounted PV system will be subject to the following design criteria: <br /> Design Wind Speed(V„it) - 160mph 3sec gust, Exposure Category-C <br /> The PV System consist of the modules, railing, and connection hardware.The system will add a <br /> dead load of approximately 3 psf to the roof. <br /> The existing roof covering is Asphalt Shingle with min. l/a" plywood decking and 2"x 4"roof trusses <br /> 24" O.C. The roofing, decking,and roof trusses are in good condition.The existing structure will be <br /> adequate for supporting the additional PV dead load and wind loads. <br /> i <br /> The securement method of the PV system is to be flush mounted to the asphalt shingle roof with the <br /> Ironridge railing and flashings/attachments.The attachments can be attached up to 72" apart.The <br /> mounts should be staggered,where possible,to allow distribution of the design loads evenly to the <br /> structure.The mounts shall be installed with a min. 5/16" lag screw with minimum 2-5/16"thread <br /> length. <br /> i <br /> 11111J/// <br /> Please see attached documents and contact me should you have any que�t+i�i�sl. <br /> Sincerely, .Z� ® -'%CEAIS••O �i�� <br /> D. Chad Godwin, PE 81360 ®' y <br /> .81 ; <br /> Exp. 02/28/2021 _ <br /> ST OF <br /> fi4 O ID P <br /> MAL <br /> �/Inllll� jr3�� <br />
The URL can be used to link to this page
Your browser does not support the video tag.