My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22538
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22538
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 1:42:09 PM
Creation date
5/12/2021 1:51:21 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-22538
Building Department - Name
WATKINS,RICHARD
Address
7135 ASHLAND DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DocuSign Envelope ID:3690B31A-DC25-4648-BAAC-225959465045 <br /> I <br /> I <br /> Wind Uplift <br /> Simplified Procedure for Components and Cladding <br /> ASCE 7-10,Section 30.5 <br /> V= 145 mph Basic Wind Speed <br /> Exposure D ASCE 7-10,Section 26.7 <br /> = 1.47 Adjustment Factor for building height,ASCE 7-10,Figure 30'!.5-1 <br /> K,= 1 Topographic Factor,ASCE 7-10,Section 26.8.2 <br /> Roof 0= 8.0 deg <br /> sanebor= 48 in Horizontal spacing of roof anchors <br /> Atrib= 21.60 sf Panel Area tributary to each roof anchor <br /> Pne80 Net Wind Design Pressure,ASCE 7-10,Figure 30.5-1 <br /> Roof Zone Zone 1 Zone 2 Zone 3 As shown in ASCE 7-10,Figure 30.5-1 <br /> 31.5 psf 49.1 psf 89.3 psf <br /> Paet=AK-tpaet30= Design Wind Uplift Pressure,ASCE 7-10,Equation 30.5-1 <br /> Zone 1 Zone 2 Zone 3 <br /> 46 psf 72 psf 131 psf <br /> paet= 16 psf Minimum Design Wind Pressure,ASCE 7-10,Section 30.2.2 <br /> Use 46 psf Use 72 psf Use 131 psf <br /> Connection to Existing Roof Framing <br /> F.S.= 1 Additional Factor of Safety applied to withdrawal force,if desired <br /> Atr;b= 21.60 tr <br /> DLpanel= 3.00 psf <br /> Zone 1 Zone 2 Zone 3 <br /> W„plift= 46 psf 72 psf 131 psf <br /> Pi,=F.S.x An;b x(0.6D-0.6W) Withdrawal force for each roof anchor <br /> Zone 1 Zone 2 Zone 3 <br /> -560.31bs -448.3lbs -415.41bs <br /> Connection Capacity <br /> db= 5/16 in Lag Screw diameter <br /> Dpea= 2.50 in Lag Screw penetration into existing framing member <br /> Southern Pine Species of wood framing <br /> CD= 1.6 Load Duration Factor for Wind Loading,NDS Table 2.3.2 <br /> Ct= 0.7 Temperature Factor,NDS Table 10.3.4 <br /> W= 235 Win Withdrawal Capacity NDS Equation 12.2-1 <br /> W'=CD x Ct x W= 263 lb/in Adjusted withdrawal value <br /> Panow=Dpen x W'= 657 lbs Based on penetration depth <br /> Zone 1 Zone 2 Zone 3 <br /> DEMAND= 5601bs 448 lbs 415 lbs <br /> Max Load=0.853 OK <br /> CAPACITY= 657 lbs 657 lbs 657 lbs <br /> I <br /> Page 3of3 V i v i . . oi6a.-. r <br />
The URL can be used to link to this page
Your browser does not support the video tag.