FA
<br /> G6iCo�'*�
<br /> SUPPLY & MANUFACTURING
<br /> TIVI
<br /> GULFIRUM
<br /> 29 GUAGE GULFRIB TM
<br /> PANEL OVER • • OVER •• r
<br /> FLORIDA PRODUCT APPROVAL • 11651.25
<br /> TM
<br /> ENGINEER LOAD TABLE:29 Ga. GulfRib"m Panel over 1x4 Wood Purlins over 15/32"Plywood
<br /> ,BU,ildings havirig.a:Roof Mean;Height s 20'-0'';°Roof.Slope:,2-"/.12"_--.12"/1:2",Gable or Hip;Roof`1Nind Sp,eedS 120= ".
<br /> 180mph„Exposure C1-'Risk Category II,-Erielosed Building; based on•Florida Building Gode,20.17:
<br /> 120 130 140 150 160 170 180
<br /> WIIND FASTENER
<br /> SPEED (MIN. do SUBSTRATE
<br /> Penetration ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER
<br /> ) SPACING SPACING SPACING SPACING SPACING SPACING SPACING
<br /> ZONE 1 #9-1 1x4,.Woo
<br /> 5x1.5" d24",TYPE 1, 24",TPE,1., ;24",TYPE 1; 24 TYPE 1,..24",TYPE 1 24",TYPE 1 24",TYPE 1
<br /> ;Purlins' ;
<br /> ZONE 2 #9-15x1.5" 1x4 Wood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1
<br /> Purlins
<br /> 1x4 Wood,
<br /> _20NE'3 , #9=15M.5" 24",TYPEA 24",TYPE 1 24",TYPE 1 ?24",TYPE 1 24",-TYPE 2 24",TYPE 2 24",-TYPE 2
<br /> .. .. Purlins ,
<br /> 1.)PANEL DESCRIPTION:GULFRIBTM,MIN.29 GA.,GRADE 98,36"COVERAGE,3/4"TALL.
<br /> 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL
<br /> 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:76.75 PSF @ 24" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, 123.5
<br /> PSF @ 24" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
<br /> 4.)SUBSTRATE: 1X4 WOOD PURLINS OVER MIN.15/32"THICK PLYWOOD.WOOD PURLINS ATTACHED TO PLYWOOD W/MIN.8D X
<br /> 21/2" RING SHANK NAILS AT 4" O.C. PURLINS AND PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017
<br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
<br /> 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING
<br /> CODE 2017.
<br /> X,�ZONE2 HIPROOF ZONES I`ar Note:Dimension(a)is defined as 10%of the minimum width of the building or
<br /> 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be
<br /> L----------------; ya less than either 4%of the minimum width of the building or 3 feet.
<br /> RIDGE i� ��/� TYPE 1 FASTENER PATTERN
<br /> x 4 Wood Purlins @ 24'O.C.Attached to Plywood with
<br /> ` I (1)8d x 2.5"Ring Shank Nails @ 4"O.C. At Panel Lap
<br /> nil
<br /> ZONE
<br /> z------------------�
<br /> —SAVE (1)#9-15 x 1-1/2"w/Sealer Washer Min.15/32"Plywood
<br /> 9"-9"-9"-9"Fastener Pattern @ 24"O.C.
<br /> ZONE 2 GABLE ROOF 1a) TYPE 2 FASTENER PATTERN
<br /> — -- i 1 x 4 Wood Purlins @ 1 T O.C.Attached to Plywood with
<br /> I (1)8d x 2.5"Ring Shank Nails @ 4"O.C.
<br /> RIDGE ; �—6.5" 2.5" 6.511 2.5"
<br /> ----- ---------------—; a
<br /> \+---------------------4 a
<br /> I
<br /> ZONE 1 (1)#9-15 x 1-1/2"w/Sealer Washer Min.15/32"Plywood
<br /> 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"Fastener Pattern @ 24"O.C.
<br /> + --------------------Y
<br /> ` ZONE 3 EAVE
<br /> FL#11651.25 R3•OCTOBER 5,2017
<br /> ® ® ays s
<br />
|