My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22543
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22543
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2021 1:55:26 PM
Creation date
5/12/2021 1:55:21 PM
Metadata
Fields
Template:
Building Department
Company Name
SOUTH PASCO HEALTH CARE PROPERTIES
Building Department - Doc Type
Permit
Permit #
20-22543
Building Department - Name
SOUTH PASCO HEALTH CARE PROPERTIES
Address
38250 A AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN-60686:A1 <br /> UDACT 2 N OT I F I E R° <br /> Universal Digital Alarm <br /> Communicator Transmitter . by Honeywell <br /> Annunciator Control System <br /> General <br /> The Universal Digital Alarm Communicator Transmitter(UDACT <br /> 2)is designed for use on Notifier Fire Alarm Control Panels and <br /> on the NCA-2 Network Control Annunciator.When used in con- <br /> junction with the NCA-2 network control annunciator, the ` <br /> UDACT2 can report the status of all'control panels on <br /> NOTI•FIRE•NETTm.The UDACT-2 transmits system status to UL - <br /> listed Central Station Receivers via the public switched tele- <br /> phone network.The UDACT 2 can be installed in the panel cab- • - <br /> inet or remotely in a separate enclosure. u. - <br /> NOTE. The UDACT-2 can also be used with legacy panels. <br /> Please refer to the UDACT-2 manual for more information. <br /> The UDACT2 .upload/download programming 'and firmware - <br /> updates are accomplished with VeriFire Tools. Refer to the Pro- <br /> gramming Section for further.details. • <br /> The UDACT-2 is capable of transmitting the status of software <br /> zones (Alarm and Trouble), System Trouble, Panel Off-Normal, <br /> Supervisory; Bell Trouble, Low Battery, and AC Fail. They <br /> UDACT2 is capable of transmitting all of the zone and point sta- <br /> tus associated with each panel. <br /> When the UDACT-2 is used with the NFS-3030, NF82-3030, <br /> and NCA-2 it is capable of reporting-up to 2,040 points.Report- <br /> ing may be in the form of points or zones(refer to the UDACT-2 <br /> manual.for specific reporting parameters). Points transmitted <br /> may be programmed for a variety of types,including fire,water- <br /> flow,supervisory,etc. 'UDACT-2 <br /> NOTE.Descriptions regarding point capacity,-listed above,are for <br /> receivers which-receive in Ademco Contact ID format. See chart . Open Collector relay driver for Total Communications Failure <br /> on page 2 for compatible receivers. or UDACT-2 trouble. <br /> Features • Real-time clock. <br /> • Extensive transient protection. <br /> • Programmable with VeriFire Tools version 6,60 or higher, . EIA-485 interface to host panel. <br /> allowing the UDACT2 programming to be uploaded/down- <br /> loaded and saved. Programming <br /> • Maximum of 14-point trouble messages transmitted per hour. The UDACT-2 programming is created and downloaded using <br /> • Dual phone lines with line voltage detect. VeriFire Tools.This enables the unit to be programmed prior to <br /> • Compact in size:.6.75"x 4.25"(17.145 x 10.195 cm). installation, be easily modified, and saved.either online or <br /> • USB port for upload/download programming. offline. A printed report with point or zone in can be <br /> Manual Test Report function. generated from VeriFire Tools for an ONYX Series panel or net-, <br /> work annunciator.The point report consists of the central station <br /> • Manual Transmission Clear function. point address,ACS point,ACS point function,panel label,panel <br /> • Mounts in a separate enclosure(ABS-8136 or UBS-1 B/R). point,type code,custom and extended label,alarm verification, <br /> • Communicates vital system status including: walktest participation,presignal,and PAS information.The zone <br /> —Independent zone fire alarm. report consists of a grid with the central station point address, <br /> ACS point address, source, ACS point function, custom label <br /> —Independent zone non-fire.alarm. and panel label.This report may be sent to the Central Station <br /> —Independent zone trouble. for their records. VeriFire Tools also supports upgrading the <br /> -Independent zone supervisory. UDACT-2 operating firmware. <br /> —AC(mains)Power Loss(programmable). <br /> —Low Battery and Earth Fault. <br /> —System Off-Normal. <br /> —12 or 24 hour test signal. <br /> —Abnormal Test Signal per new UL requirements. <br /> —EIA-485 Communication Bus Failure. <br /> • Annunciation of UDACT-,2 Troubles including: loss of phone <br /> lines, communication failure with either Central Station,total <br /> communications failure. <br /> • Individual LEDs for: Power, EIA-485 Loss, Manual Test, Kis- <br /> soff, Comm Fail, Primary Line Seize, Secondary Line Seize <br /> and Modem Communications. <br /> DW60686:A1 4/2/12—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.