My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22543
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22543
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2021 1:55:26 PM
Creation date
5/12/2021 1:55:21 PM
Metadata
Fields
Template:
Building Department
Company Name
SOUTH PASCO HEALTH CARE PROPERTIES
Building Department - Doc Type
Permit
Permit #
20-22543
Building Department - Name
SOUTH PASCO HEALTH CARE PROPERTIES
Address
38250 A AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DN-6724:83 <br /> FCM-1 (A) & FRM-1 (A) NOT 1 F 1 E R° <br /> Series <br /> Control and Relay Modules by Honeywell <br /> Intelligent Addressable Devices <br /> General <br /> FCM-1(A)Control Module: The FCM-1(A)Addressable Con-- <br /> trol.Module provides Notifier intelligent fire alarm control pan- <br /> els a circuit for Notification Appliances (horns, strobes, <br /> speakers,etc.).Addressability allows the FCM-1(A)to be acti- <br /> vated; either manually or through panel programming, on a .. <br /> select(zone or area of coverage)basis. .�.� <br /> FRM-1(A)Relay Module: The FRMA(A) Addressable Relay "'E•'"""''` <br /> Module.provides the system with a dry-contact output for acti- <br /> vating a variety of auxiliary devices, such as fans, dampers, <br /> control equipment,etc.Addressability allows the dry contact to <br /> be activated, elther.manually or through panel programming, <br /> on a select basis. <br /> FlashScan®.(U.S.Patent 5,539,389)is a communication pro- <br /> tocol developed by .NOTIFIER Engineering that greatly y.. <br /> enhances the speed of communication between analog intelli- <br /> gent devices: Intelligent devices. communicate in a grouped <br /> fashion. If one of the devices within the group,has new infor- <br /> mation,the panel CPU stops the group poll and concentrates <br /> on single points.The net effect is response speed greater than <br /> five times that of other designs. FCM-1(A) <br /> Features <br /> • Built-in,type identification automatically identifies these The FCM-1(A)is configured.for a single Class B(Style Y)or <br /> devices to the control panel: Class A(Style Z)Notification Appliance Circuit. <br /> • Internal circuitry and relay powered directly by two-wire The FRM-1(A) provides two Form-C dry contacts that <br /> SLC loop.The FCM-1(A)module requires power(for horns, switch together. <br /> strobes,etc:),or audio(for speakers). <br /> • Integral LED "blinks" green each time a communication is Operation, <br /> received from the control panel and turns on in steady red Each FCM-1(A)or FRM-1(A)uses one of 159 possible module <br /> when activated. addresses on a SLC loop (99 on CLIP loops). It responds to. <br /> • LED blink may be deselected globally(affects all devices). regular polls from the control panel and reports its type and <br /> High noise immunity(EMF/RFI). status, including the open/normal/short status of its Notifica- <br /> tion Appliance Circuit (NAC). The LED blinks with each poll <br /> The FCM-1(A) may be used to switch 24-volt NAC power,. . <br /> • audio(up to A) may <br /> be received. On command, it activates its internal relay. The <br /> FCM=1(A)supervises Class B (Style Y) or Class A (Style Z) <br /> • 'Wide viewing angle of LED. notification or control circuits. <br /> • SEMS screws with clamping plates for wiring ease. Upon code command from the panel, the FCM-1(A) wily dis <br /> • Direct-dial entry of address 01— 159 for FlashScan loops, connect the supervision and connect the external power sup- <br /> 01 —99 for CLIP mode loops. ply in the proper polarity across the load device. The <br /> Speaker, and audible/visual applications may be wired for disconnection of the supervision provides a positive.indication <br /> Class B or A(Style Y or Z). to the panel that the control relay actually turned ON.*The <br /> external power supply is always relay isolated from the com'- <br /> Applications munication loop so that a trouble condition on the external <br /> power supply will never interfere with the rest of the system. <br /> The FCM-1(A)'is used to switch 24 VDC audible/visual power, Rotary switches set a unique address for each module. The <br /> high-level audio (speakers). The FRM-1(A) may be pro address may be set before or after mounting. The built-in. <br /> grammed to operate dry contacts for applications such as door TYPE CODE(not settable)will identify the module to the con- <br /> holders or Air Handling Unit shutdown, and to reset four-wire trol panel,so as to differentiate between a module and a sen- <br /> smoke detector power. sor address. <br /> NOTE.Refer to the SLC Manual(PN 51253)for details regarding <br /> releasing applications with the FCM-1(A).Refer to the FCM-I-REL Specifications for FCM-1(A) <br /> datasheet(DN-60390)for new F/ashScanO releasing applications. <br /> Normal operating voltage: 15 to 32 VDC. <br /> Construction Maximum current draw: 6.5 mA(LED on). <br /> • The face plate is made of off-white heat-resistant plastic. Average operating current: 350 pA direct poll,375 pA group <br /> • Controls include two rotary switches for direct-dial entry of poll with LED flashing, 485 pA Max. (LED flashing, NAC <br /> address(01-159). shorted.) <br /> DN-6724:B3.2/17/2011—Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.