Laserfiche WebLink
a <br /> L-Series Specifications <br /> General <br /> System Sensor L-Series chimes and chime strobes shall mount to a standard 4 x 4 x 11/z-inch back box,4-inch octagon back box,single- <br /> gang 2 x 4 x 11/8-inch back box,or double-gang back box.A universal mounting plate shall be used for mounting products.The notification <br /> appliance circuit wiring shall terminate at the universal mounting plate.Also,System Sensor L-Series products,when used with the <br /> Sync•Circuit Module accessory,shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or <br /> 24 volts.When used with the Syno•Circuit Module,12-volt rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; <br /> 24-volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts.Indoor L-Series products shall operate between <br /> 32 and 120 degrees Fahrenheit from a regulated DC,or full-wave rectified,unfiltered power supply.Chime strobes shall have field-selectable <br /> candela settings of 15,30,75,95,110,135,and 185 for wall units and 15,30,75,95,115,150,and 177 for ceiling units. <br /> Chime Strobe Combination <br /> The chime strobe shall be a System Sensor SpectrAlert Advance Model listed to UL 1638 and UL 464.The chime strobe shall comply <br /> with the Americans with Disabilities Act requirements for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage <br /> range.The strobe light shall consist of a xenon flash tube and associated lens/reflector system.The chime shall have two audibility options <br /> and an option to switch between temporal three pattern,non-temporal(continuous)pattern, 1 second chime pattern, 1/4 second chime <br /> pattern,5 second whoop chime pattern.These options are set by a multiple position switch. <br /> Synchronization Module <br /> The module shall be a System Sensor Sync-Circuit listed to UL 464 and shall be approved for fire protective service.The module shall <br /> synchronize SpectrAlert strobes at 1 Hz and all available chime.tones.Also,while operating the strobes,the module shall silence the chimes <br /> on chime/strobe models over a single pair of wires.The module shall mount to a 411/16 x 4"/16 x 2 1/8-inch back box.The module shall also <br /> control two Style Y(class B)circuits or one Style Z(class A)circuit.The module shall synchronize multiple zones.Daisy chaining two or more <br /> synchronization modules together will synchronize all the zones they control.The module shall not operate on a coded power supply. <br /> Physical/Electrical Specifications <br /> Standard OperatingTemperatu're 32°F to 120°F(0°C to 49°C) <br /> Humidity Range 10 to 93%non-condensing <br /> Strobe Flash Rate 1 flash per second <br /> Nominal Voltage Regulated 12VDC or regulated 24DC/FWR1 <br /> Operating Voltage Rangez 8 to 17.5V(12V nominal)or 16 to 33V(24V nominal) <br /> Operating Voltage Range with MLD3 8.5 to 17.5V(12V nominal)or 16.5 to 33V(24V nominal) <br /> Input terminal wire gauge 12 to 18 AWG <br /> Chime strobe dimensions(including lens) 5.6 in L x 4.7 in W x 1.91 in D(143 mm L x 119 mm W x 49 mm D) <br /> Chime dimensions 5.6 in L x 4.7 in W x 1.25 in D(143 mm L x 119 mm W x 32 mm D) <br /> Ceiling Chime strobe dimensions(including lens) 6.8"Dia.x 2.47"D(173.5mm Dia.x 62.7mm D) <br /> SBBRL(red wall surface mount back box) 5.6 in L x 4.7 in W x 4.3 in D(142 mm L x 119 mm W x 109 mm D) <br /> SBBWL(white wall surface mount back box) 5.6 in L x 4.7 in W x 4.3 in D(142 mm L x 119 mm W x 109 mm D) <br /> SBBCRL(red ceiling surface mount back box) 6.9"Dia.x 2.5"D(175.8mm Dia.x 63.5mm) <br /> SBBCWL(white ceiling surface mount back box) 6.9"Dia.x 2.5"D(175.8mm Dia.x 63.5mm) <br /> Notes: <br /> 1.Full Wave Rectified(FWR)voltage is a non-filtered,time varying power source that is used on some power supply and panel outputs. <br /> 2.CHS products will operate at 12 V nominal only for 15 and 30 cd. <br /> UL Current Draw Data <br /> UL Max.Chime Current Draw(mA RMS) <br /> 6-17.5 Volts 16-33 Volts <br /> Sound Pattern dB DC DC FWR <br /> 1 Second Chime High 5 8 9 <br /> 1 Second Chime Low 5 8 9 <br /> 1/4 Second Chime High 6 10 10 <br /> 1/4 Second Chime Low 5 9 9 <br /> Temporal Chime High 7 10 10 <br /> Temporal Chime Low 6 9 9 <br /> 5 Second Whoop High 12 15 16 <br /> 5 Second Whoop Low 7 10 11 <br /> Coded High 12 15 16 <br /> 'This data represents coding at 3 chimes per second.Actual current draw will vary depending upon coding selected. <br />