Laserfiche WebLink
21 Tamper- Resistant Receptacles in accordance with 406.11 of the.2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water,pipe insulation <br /> Insulation for'hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping V.inch (19:1 mm)and larger in nominal diame_ter._ <br /> Piping:serving more than.one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the:Water heater to a distribution manifold._ <br /> Piping located under a floor-slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower.door test shall be provided before C.O. <br /> 26.A copy of the enemy tack shall be with permit at all times <br /> 27. Copy of lhal.'insulation report shall be provided with permit before rinaL <br /> 28.No fence,pool onscreen enclosure :is issued with:this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.=Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />