Laserfiche WebLink
23. Tamper-'Resistant Receptacles in accordance with 406.11 of the 2016 ME.-C <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least.10- <br /> feet around the structure. <br /> 25. R403.5.3Hot.Water.pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance_ (R value) of,R-3 shall.be applied to the <br /> following:. <br /> Piping 3/: inch (1.9.1 mm)and larger in nominal diameter: <br /> Piping:serving more than one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water-heater to a.distribution manifold. <br /> Piping:located under.a floor slab. <br /> Buried in piping.' <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.-Slower door test shall be provided before C.O; <br /> 26.A copy ofthe enerey cacls shall&with permit at all times. <br /> 27.. Cove of final insulation-report shall be provided with permit before fnab <br /> 28.No fence,pool onscreen enclosure :is issued yith:th is.permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-..Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way. <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />