Laserfiche WebLink
21 Tamper- Resistant.Receptacles in accordance with 406.11 of the-2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots shall.be sodded before final at.least 10 <br /> feet around the structure. <br /> 25. R403.5.31-lot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be appl I.ied to the <br /> following: . <br /> Piping.3h inch (1.9.1 mm)and larger in.nominal diameter. <br /> Piping.serving more than-one dwelling unit: <br /> Piping located outside the conditioned space. <br /> Piping from the water heater-to a-distribution manifold:. . <br /> Piping.located under,a floor slab. <br /> Buried-in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.-Blower door test shall be provided before C.O: <br /> 26.A copy of the en cacls shall be.with permit at all times <br /> 27. Copy of final insulation report shaft be provided with permit before r1nal <br /> 28. No fence,pool or screen-enclosure :is issued with thispermit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.0 Florida Building Code Oh Edition <br /> R.O.W.--Right of,Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />