Laserfiche WebLink
23. Tamper-Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall be sodded before final at least.10 <br /> feet around the structure. <br /> 25. R403.5.3Hotwaterpipe insulation <br /> Insulation for hot water.-pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following:, <br /> Piping-3I< inch (1.9:1 mm) and larger in-nominal diameter: <br /> Piping serving more than.one dwelling unit: <br /> Piping located outside the conditioned space. <br /> Piping from the;waterheaterto a:distribution manifold:, <br /> Piping.located under.a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower door test shall be provided before C-O: <br /> 26.A copy of the energy.each shall be with permit at all times <br /> 27. CopV of final.insulation report shall be provided with permit before rinal <br /> 28.No fence, Pool or sereen enclosure :is issued with A&permit <br /> F.F.E.-Finished Floor Elevation <br /> ERG-Florida Building Code 6th Edition . <br /> R.,O.W.-Right-of Way <br /> A.D.A. Americans with Disabilities Act, N.E.C.-National Electric Code (2016) <br />