Laserfiche WebLink
.j <br /> Q� <br /> Single .Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall be a minimum of 8" above the road elevation and an engineered-site plan. <br /> 2. Lots shall be graded to.comply with R401.3 of the F.B.C. <br /> 3. Compaction test required if 24".or-more of fill;dirt is brought in at any one.place. <br /> 4. Tie in survey required before pouring concrete. <br /> 5. Driveways require a R:OM. use permit. All 4 sides-of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 7: All property markers shall be uncovered.and marked at time of first inspection. <br /> .. <br /> 8: All A.,D.A.requirements shall:be:met: - <br /> 9. .No electric, plumbing;mechanical, or framing shall.be covered without an inspection and <br /> approval first. <br /> 10.. All Garages shall conip Y 1 -with section R302:6 of the F.B-C. Fire"S aration <br /> . . <br /> 1.1. Appliances shall not be installed in a location where subject to mechanical damage unless <br /> protected by:approved barriers. M303;4 of the F.B.0 <br /> 12. Waterheaters shall comply with section P607.3 ofthe F:B:C: . <br /> U.' Foundation supports for A/.0 tiriits.shall be raised"at least 3" above finished grade. M1308:1 . <br /> 14. Return air in all bedrooms. F.B.-C.. M1620.4 <br /> 15. Smoke detectors are to be installed in accordance with R313.1 of the F.B.C. <br /> 16. All glazing requirements are to be in accordance with R308A of the F.B.C. <br /> 17. All means of egress are to be in accordance-with R311 of the F.B.C. <br /> 18. "Green gypsum board'' shall riot be used as a backer in showers or tubs.R702.4.2 F.B.C. <br /> 19. Combination-type AM breakers are required at all locations requiring an AM type breaker-. <br /> 20. Carbon monokide alarms will be required in new construction that uses fossil-burning heating. <br /> or appliances or an attached garage.' They shall.be installed in accordance with the F.B.G: <br /> 21. All plumbing,mechanical; and electrical shall be separate from unit to unit. This includes all <br /> underground plumbing and electric. <br /> 21 All 2016 N:E.C.'Codes will be enforced. <br />