Laserfiche WebLink
' DESIGN PRESSURE RATING IMPACT RATING <br /> 52-1/8"MAX.BUCK WIDTH VARIES PER REINFORCEMENT .NOT RATED FOR <br /> LEVEL,SEE SHEETS 6-7 IMPACT RESISTANCE <br /> 82-1/8"MAX.BUCK WIDTH SHEEP SEE 3 MAX.O.C. 12"MAX. 52.110"MAX.BUCK WIDTH <br /> — I SEE SHEETS 1-1/4" <br /> B.SEE_ 28-1/8, A,5�r_. _ ., 12"MAX. — �r <br /> SHEET 3 —MAX.O.C. IT MAX. SHEETS J i7op SASH VISIBLE � �_ 52.1/8"MAX.BUCK WIDTH SHEET4' —� � 8&9 1 <br /> LIGHT WIDTH 28-1/8^ _ .1 <br /> A.SEE_—_ _. h 86.338'• B,SEE _. —MAX.O.C. `I�—IT MAX. C.SEE - I <br /> SHEETS II 12"rMAX. / TOP MAX SHEET3 SHEET4 ° I <br /> '• — + I SASH BUCK <br /> 1 EQUALLY I T A.SEE--' 112MAX.EQUALLY I 15.112"MAX.O.C. SPACED j I 1LIGHT ISAI "MAX.O.C.HEIGHT SHEEr3'SPACED ANCHORS PER I III TABLES 5&7 I HEIGHT — E PER QUALLY ED 11112'MAX.O.C. I l <br /> ANCHORS <br /> 6&7 I / I ANCHORS PER 1 X j I / 84• <br /> X i i I-1 84, X i' TABLES 6&7;.. I I M62"AX. a X I L BUCK <br /> �J M AX. �_ HEIGHT <br /> X I 1D"MAX O.C. HBUCK EIGHT X_ 10'MAX.O.C. I 1D"MAX.IO.C. BUCK AS SHOWN <br /> ' X i i �. , y HEIGHT X L� (86.338„ <br /> _ g_OTTOM _ , I I 13—BOLT IMAX.O.C. i L--/77 MAX.) <br /> j 13.S07"MAX O.C. EQUALLY /7 SASH 13.807"MAX D.C. EQUALLY,_ "/ j <br /> EQUALLYI I VISIBLE SPACED 7' ! / <br /> SPACED1 i�_ SPACED LIGHT —'�— ANCHORS PER I r SEE T I L <br /> ANCHORS PER' I / ANCHORS PER HEIGHT - TABLES I i SHEETS J f <br /> TABLES6&7I I A I TABLES6&7 I A I I /// 1 A 8$g C <br /> 1 I 11 I Jy.. <br /> 8-1l2-MAX <br /> NOANCHORSATSILL `R NO ANCHORSATSLL _J NO ANCHORS AT SILL J <br /> B� ` j SEESILLWEEP- B�— SEE SILL WEER B-� SEESILLWEEP- D- ---•-- 1-1/4"•—+-� r SEEBILLWEEP- <br /> -NOTCH DETAILS, BOTTOM SASH VISIBLE `r�NOTCH DETAILS, 1-+ 54'MAX BUCK WIDTH -NOTCH DETAILS, NOTCH DETAILS, <br /> SHEET3 LIGHT WIDTH SHEETS SHEETS SHEET4 <br /> ELEVATION FOR TYP.EQUAL LEG FRAME ELEVATION FOR TYP.FLANGE FRAME ELEVATION FOR TYP.FLANGE FRAME ELEVATION FOR TYP.FIN OR J-CHANNEL FRAME <br /> SHOWN WITH EQUAL-CITE CONFIGURATION SHOWN WITH ORIEL/PROVIEW CONFIGURATION SHOWN WITH STANDARD COTTAGE CONFIGURATION SHOWN WITH EQUAL-LITE CONFIGURATION <br /> FOR CUSTOMCOTrAGE CONFIGURATION-UPTO ANCHORED THROUGH THE NAIL-FIN - <br /> GENERAL NOTES:SERIES 5460 NON-IMPACT RESISTANT DOUBLE HUNG WINDOW 75^HEIGHT SEE rAeLEsaa (SIMILAR ANCHOR DIMENSIONS FOR OTHER CONFIGURATIONS) <br /> 1)THIS PRODUCT HAS BEEN DESIGNED&TESTED TO COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE.INCLUDING THE HIGH VELOCITY HURRICANE ZONE(HVHZ). <br /> 2 SHUTTERS ARE REQUIRED WHEN USED IN WIND-BORNE DEBRIS REGIONS. GENERAL NOTES.......................................-........1 <br /> ELEVATIONS............................. ..............._._..1 <br /> 3)FOR MASONRY APPLICATIONS IN MIAMI-DARE COUNTY,USE ONLY MIAMI-DADE COUNTY APPROVED MASONRY ANCHORS.MATERIALS USED FOR ANCHOR EVALUATIONS WERE SOUTHERN PINE, FRAME,GLASS 8 ANCHOR OPTIOPTIONSS................2 <br /> ASTM C90 CONCRETE MASONRY UNITS AND CONCRETE WITH MIN.KSI PER ANCHOR TYPE. INSTALLATION,FLANGE&EQUAL LEGBOX.....3 <br /> 4)ALL WOOD BUCKS LESS THAN 1-1/2"THICK ARE TO BE CONSIDERED 1X INSTALLATIONS.1X WOOD BUCKS ARE OPTIONAL IF UNIT IS INSTALLED DIRECTLYTO SUBSTRATE.WOOD BUCKS INSTALLATION.INTEGRAL FIN&J-CHANNEL...4 <br /> DEPICTED AS 2X ARE 1-112"THICK OR GREATER.1X AND 2X BUCKS(WHEN USED)SHALL BE DESIGNED AND SECURED TO PROPERLY TRANSFER LOADS TO THE STRUCTURE.WOOD BUCK DESIGN <br /> AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER(EOR)OR ARCHITECT OF RECORD,(AOR). GLAZING DETAILS ES................................................5 <br /> 5 ANCHOR EMBEDMENT TO BASE MATERIAL SHALL BE BEYOND WALL DRESSING OR STUCCO.USE ANCHORS OF SUFFICIENT LENGTH TO ACHIEVE REQUIRED MIN.EMBEDMENT.INST.ANCHORS DESIGN PRESSURES............._...........................S-7 <br /> ANCHOR QUANTITIES......... 10 <br /> _ SHOULD BE SEALED.OVERALL SEALING/FLASHING STRATEGY FOR WATER RESISTANCE OF INSTALLATION SHALL BE DONE BY OTHERS AND IS BEYOND THE SCOPE OF THESE INSTRUCTIONS. """"""""""""'"""' <br /> 0)1/4"MAX.SHIMS ARE REQUIRED AT EACH ANCHOR LOCATION WHERE THE PRODUCT IS NOT FLUSH TO THE SUBSTRATE,USE SHIMS CAPABLE OF TRANSFERRING APPLIED LOADS. EXTRUSION PROFILESST...................................10 <br /> ASSEMBLY&PARTS LIST...................................11-12 <br /> 7)DESIGN PRESSURES: <br /> A.NEGATIVE DESIGN LOADS BASED ON STRUCTURAL TESTING AND GLASS PER ASTM E1300. CODES/STANDARDS USED: <br /> B.POSITIVE DESIGN LOADS BASED ON WATER TEST PRESSURE,STRUCTURAL TESTING AND GLASS PER ASTM E1300. •2017 FLORIDA BUILDING CODE(FBC),6TH EDITION <br /> C.DESIGN LOADS ARE BASED ON ALLOWABLE STRESS DESIGN,ASO. .2014 FLORIDA BUILDING CODE(FBC),5TH EDITION <br /> 8)THE ANCHORAGE METHODS SHOWN HAVE BEEN DESIGNED TO RESIST THE WINDLOADS CORRESPONDINGTO THE REQUIRED DESIGN PRESSURE.THE 33-1/3%STRESS INCREASE HAS NOT -ASTM E130D-09 <br /> BEEN USED IN THE DESIGN OF THIS PRODUCT.THE 1.6 LOAD DURATION FACTOR WAS USED FOR THE EVALUATION OF ANCHORS INTO WOOD.ANCHORS THAT COME INTO CONTACT WITH •ANSUAF&PA NDS-2015 FOR WOOD CONSTRUCTION <br /> OTHER DISSIMILAR MATERIALS SHALL MEET THE REQUIREMENTS OF THE FLORIDA BUILDING CODE FOR CORROSION RESISTANCE. -ALUMINUM DESIGN MANUAL,ADM-2015 <br /> 9)METAL SUBSTRATE TO MEET MIN.STRENGTH AND THICKNESS REQUIREMENTS PER CURRENT FLORIDA BUILDING CODE AND TO BE REVIEWED BY THE AUTHORITY HAVING JURISDICTION. .AISI S100-12 PRODUCT REVISED <br /> — <br /> 10)REFERENCES:TEST REPORTS FTL-8006;ELCO ULTRACON NOA;ELCO CRETEFLEX NOA;ELCO AGGRE-GATOR NOA;ENERGI WINDOW AND DOOR PROFILES,LTD WHITE&BRONZE/LIGHTER •AISC 36D-10 - Bw6J.'ng' I�Lhe FIxMe <br /> G.rdc <br /> SHADES OF CAP COATED PVC EXTRUSION NOBS;NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION,ANSI/AF&PA NOS&ALUMINUMGN UAL Arcgnanco No .Og7�r1 <br /> 11)APPLICABLE EGRESS REQUIREMENTS TO BE REVIEWED BY BUILDING OFFICIAL, x� �(LYN //i Revision: Expiration Do[a rr <br /> �\ARN'cEmsN��l : UPDATED TO FBC 2017.-JR- B <br /> r <br /> USER INSTRUCTIONS: 0 S '.l <br /> �'• •fC M Dade Prudect Cn•.#r <br /> 1)DETERMINE THE SITE SPECIFIC,WINDOW OPENINGSDESIGN PRESSURE REQUIREMENT FROM ASCE 7. Q.' '•� � 06/06/17 <br /> 2)DETERMINE THE MOST SUITABLE ANCHOR GROUP FROM TABLES 2 OR 3 ACCORDING TO THE I T� <br /> INSTALLATION CONDITIONS. _�.: No.58705 *= <br /> 3)KNOWING YOUR GLAZING OPTION(TABLE 1).WINDOW CONFIGURATION AND SIZE,DETERMINE YOUR WINDOWS DESIGN _ _ <br /> PRESSURE FROM TABLES 4 OR 5.IT MUST EQUAL OR EXCEED THE DESIGN PRESSURE REQUIREMENT FOR THE WINDOW Doecription; Drana W. <br /> OPENING OBTAINED IN STEP I. �� •. 1o70TECHNOLOGYDRNE GENERAL NOTES&ELEVATION J ROSOWSKF <br /> �./ <br /> 4)DETERMINE THE ANCHOR QUANTITY FROM TABLES 0 OR 7.VERIFY THE ANCHORISUBSTRATE WILL MEET REQUIREMENTS O STATE [V; N.VENICE,FL 34275 <br /> .f� TiHa: Data: <br /> FOR YOUR OPENINGS CONDITION FROM TABLES 2 OR 3,AND THAT ALL MIN.REQUIREMENTS FROM THIS SHEET-SET ARE MET. %� ••.F[ORIDP.. �` (941}480.1600 DOUBLE HUNG WINDOW INSTALLATION-NI 05/15/15 <br /> 5)INSTALL AS PER SHEET 3 FOR THRU-FRAME INSTALLATION OR SHEET 4 FOR INTEGRAL FIN INSTALLATION. / s \`G <br /> // `` PGTGOI DUSUsm,INC. Sertes/uodel. Scale: sh-L Draw�np No. Rer: <br /> NDTE:DESIGN PRESSURE RATING OETER(AINATION IS THE SAME PROCESS FOR ALL FRAME TYPES(JCHANNEL,FLANGE, ///I 11111 AuwGltls RESERVED <br /> INTEGRAL FIN OR EQUAL LEGIBOX). ALYNN MILLER,P.E. DH-5460 NTS 1 OF 12 MD-DH5460-01 B <br /> P.E$56705 CERi.OF AUTH.A29296 <br />