Laserfiche WebLink
REVISIONS <br /> REV DESCRIPTION DATE APPROVED <br /> NOTES: A REVISED INSTALLATION DETAILS 08/07/15 R.L. <br /> 1) THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO B REVISED ANCHORING NOTES 06/05/17 R.L. <br /> COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE. <br /> 2) WOOD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY <br /> TRANSFER ALL LOADS TO STRUCTURE. FRAMING IS THE ANCHORING NOTES: <br /> RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 1) FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 WOOD <br /> 3) ALLOWABLE STRESS INCREASE OF 1/3 WAS NOT USED IN THE SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM <br /> DESIGN OF THE PRODUCT SHOWN HEREIN. WIND LOAD DURATION EMBEDMENT. LOCATE ANCHORS AS SHOWN IN INSTALLATION DETAILS <br /> FACTOR Cd=1-6 WAS USED FOR WOOD ANCHOR CALCULATIONS. SHEET 3. <br /> 4) APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS 2) FOR ANCHORING INTO CONCRETE USE 3/16" ELCO ULTRACON <br /> PRODUCT IN WIND BORNE DEBRIS REGIONS UP TO WIND ZONE 3. TAPCON WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM <br /> 5) DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS EMBEDMENT WITH 1" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS <br /> DOCUMENT APPLY ONLY TO MULLION. WINDOWS MUST BE APPROVED SHOWN IN INSTALLATION DETAILS SHEET 4. <br /> UNDER SEPARATE APPROVAL. 3) FOR ANCHORING INTO METAL FRAMING USE #10 SMS OR SELF <br /> 6) SINGLE WINDOWS TO BE MULLED ARE NOT LIMITED TO THOSE DRILLING SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 3 <br /> SHOWN IN THIS DRAWING. WINDOWS MUST BE MANUFACTURED BY MI THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE <br /> WINDOWS AND DOORS, INC. ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. <br /> 7) DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE 4) FOR ATTACHING WINDOW UNITS TO MULLION USE #10 SELF TAPPING <br /> LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM <br /> WINDOW OR DOOR UNIT. EMBEDMENT OF THREE THREADS PAST THE MULLION WALL. LOCATE <br /> 8) UNITS MAY BE MULLED TOGETHER INDEFINITELY AS LONG AS SINGLE SCREWS 6" FROM EACH MULLION END AND 12" MAX. O.C. <br /> UNIT WIDTH AND HEIGHT ARE NOT EXCEEDED AND MULLION IS THEREAFTER. STAGGER SCREWS AT EACH WINDOW. <br /> ANCHORED AS SHOWN HEREIN. <br /> 9) MULLION VERTICAL INSTALLATION IS SHOWN, MULLION MAY BE USED 5) ALL FASTENERS TO BE CORROSION RESISTANT. <br /> IN HORIZONTAL APPLICATIONS AS LONG AS DIMENSIONS INDICATED 6) INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH <br /> HEREIN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND <br /> TO THIS DOCUMENT. ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS <br /> LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: <br /> A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 <br /> B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 4,200 PSI. <br /> C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, <br /> DESIGN PRESSURE TABLE INSTRUCTIONS: TYPE 1 (OR GREATER). <br /> 1) DEFINE REQUIRED DESIGN LOAD PER FLORIDA BUILDING CODE D. METAL - STEEL 18GA (.048") FY=33KSI/FU=52KSI OR <br /> CHAPTER 16. ALUMINUM 6063-T5 FU=30KSI .0625" THICK MINIMUM. <br /> 2) DETERMINE TRIBUTARY WIDTH AND MULLION SPAN BASED ON <br /> PRODUCT TO BE INSTALLED. SEE FORMULA FOR TRIBUTARY WIDTH. <br /> 3) LOCATE MULLION SPAN (UNIT HEIGHT) AND TRIBUTARY WIDTH. AT <br /> THE INTERSECTION OF ROW AND COLUMN CONTAINING THE MULLION <br /> SPAN AND TRIBUTARY WIDTH RESPECTIVELY IS THE MULLION RATING <br /> FOR PRODUCT IN STEP 2. <br /> MULLION RATING MUST BE EQUAL OR GREATER THAN REQUIRED <br /> DESIGN PRESSURE OBTAINED IN STEP 1. <br /> SIGNED: 10/17/2017 <br /> TRIBUTARY WIDTH = W1 2 W2 M650 IWDOWESTMA KETS AND DOORS \`"'J\s 111I II/o <br /> STREET <br /> GRATZ, PA 17030-0370 `v••�%GENSF••cP<� <br /> M-2285 - VERTICAL MULLION =*�•//�0ayOFX, <br /> ` <br /> 84" MULLION SPAN �a�y(gq( <br /> TABLE OF CONTENTS NOTES ��, T4 <br /> SHEET NO. DESCRIPTION V.L. <br /> OS-01833 N: DWG NO. RE A, <br /> DRAWN:DOR�O'.lsz <br /> NOTES � <br /> SCALE DATE SHEET ////1111 <br /> 2 CONFIGURATIONS AND DP CHART NTS 01/11/12 1 OF 4 <br /> 3 INSTALLATION DETAILS L.ROBERTO LOMAS P.E. Luis R. Lomas P.E. <br /> 1432 WOODFORD RD LEWISVILLE,NC 27023 FL No.: 62514 <br /> 4 COMPONENTS 434-668-0609 illomas@lTlomaspe.wm <br />