My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22612
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22612
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 1:49:06 PM
Creation date
5/17/2021 1:44:27 PM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-22612
Building Department - Name
SANTA CRUZ,THOMAS DAVID
Address
38920 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Wind Parameters <br /> Wind Speed 145 mph <br /> Exposure Category D <br /> Roof Angle, 0 18.0 deg <br /> Product Information <br /> No.of Panels 10 <br /> Weight 3.00 psf including mounting system <br /> Installed Area 175.8 ft2 <br /> No.of Connectors 13 <br /> Total Existing Roof Load=DLRooF+(LLRooF or Snow)x Spacing <br /> 60.04 pif <br /> Total New Roof Load=DLRooF+DLADD+(LLRooF or Snow)x Spacing <br /> 26.04 plf <br /> Change in Demand=(Total New Load-Existing Load)/Existing Load <br /> -56.63% <br /> Total New Gravity Loads are less than Existing Loads. OK <br /> Code References <br /> 2015 IEBC Section 707.2 states: <br /> "Where addition or replacement of roofing or replacement of equipment results in additional dead loads,structural components supporting <br /> such reroofing or equipment shall comply with the gravity load requirements of the International Building Code. EXCEPTION 1.Structural <br /> elements where the additional dead load from the roofing or equipment does not increase the force in the element by more than 5 percent." <br /> 2015 IRC Section AJ501.4 states: <br /> "The minimum design loads for the structure shall be the loads applicable at the time the building was constructed,provided that a dangerous <br /> condition is not created. Structural elements that are uncovered during the course of the alteration and that are found to be unsound or <br /> dangerous shall be made to comply with the applicable requirements of this code." <br /> 2017 FBC Section AJ104.1 states: <br /> "Detached one-or two-family dwellings that are not irregular buildings under Section R301.2.2.2.5 and are not undergoing an extensive <br /> reconstruction shall not be required to be evaluated." <br /> Page 2 of 3 • • <br /> viva • . <br />
The URL can be used to link to this page
Your browser does not support the video tag.