Laserfiche WebLink
Page 3 of 6 <br /> ® MICROMATIC° STANDARD <br /> 5 A RESPONSE UPRIGHT <br /> SPRINKLER VK100 (K5.6) <br /> The Viking Corporation,210 N Industrial Park Drive,Hastings MI 49068 <br /> Telephone:269-946-9501 Technical Services:877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingeorp.com <br /> Visit the Viking website for the latest edition of this technical data page:www.vikinggroupinc.com <br /> TABLE 1:AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES <br /> Sprinkler Temperature S°prinkler Nominal Mxmum Ambient <br /> g11ir Bulb Dolor <br /> Classifica#ion Temperature Ra#ing' Ceiling Tempe.rature� <br /> Ordinary 135 OF (57°C) 100 OF(38°C) Orange <br /> Ordinary 155 OF(68 °C) 100 OF(38 °C) Red <br /> Intermediate 175 OF(79°C) 150 OF(65°C) Yellow <br /> Intermediate 200 OF (93°C) 150 OF (65'C) Green <br /> High 286 OF (141 °C) 225 OF(107°C) Blue <br /> Extra High 360 OF (182°C) 300 OF(149°C) Mauve <br /> Ultra High' 500 °F (260 'C) 465 OF (240'C) I Black <br /> Sprinkler Finishes: Brass, Chrome,White Polyester, Black Polyester, and ENT <br /> Corrosion-Resistant Coatings4:White Polyester, Black Polyester,and Black PTFE in all temperature ratings. ENT in all temperature <br /> ratings except 135 OF(57 °C). Wax-Coated Brass and Wax over Polyesters for sprinklers with the following temperature ratings: <br /> 155 OF(68°C) Lt. Brown Wax 175 OF(79°C)Brown Wax 200 OF(93°C) Brown Wax 286 OF (141 °C) Dk. Brown Wax-' <br /> Footnotes <br /> 'The sprinkler temperature rating is stamped on the deflector. <br /> 2 Based on NFPA-1 3.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. <br /> Refer to specific installation standards. <br /> 'Sprinklers of Ultra-High temperature rating are intended for use inside ovens,dryers,or similar enclosures with normal operating temperatures above <br /> 300 OF(149°C).Where the ambient temperature around the Ultra-High temperature rated sprinkler is significantly reduced below 300 OF(149°C), <br /> response time may be severely retarded. <br /> a The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These <br /> tests cannot and do not represent all possible corrosive environments. Prior to installation,verify through the end-user that the coatings are com- <br /> patible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exterior surfaces <br /> only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings.For ENT coated automatic sprinklers,the waterway is coated. <br /> s Wax melting point is 170 OF(76°C)for 286 OF(141 °C)temperature rated sprinklers. <br /> Form No. F_052014 18.10.11 Rev 17.1.P65 <br />