My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22643
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22643
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:28:44 PM
Creation date
5/17/2021 2:28:39 PM
Metadata
Fields
Template:
Building Department
Company Name
PEEPLES FAMILY CORP INC
Building Department - Doc Type
Permit
Permit #
20-22643
Building Department - Name
PEEPLES FAMILY CORP INC
Address
38345 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ROOF OESIGN CONSIDERATUOUS <br /> Perimeter Half Sheet Table •R-Value <br /> —Thermal Resistance:The number of degrees difference between <br /> Number of Number of Number of two surfaces(energy difference)that is required to obtain an <br /> Building Building EverGuard® EverGuard® EverGuard® energy flow of 1 BTU through a 1-square-foot(0.0929 sq m) <br /> TPO 60" PVC 60" TPO 72" sample of a given material thickness in one hour. <br /> Width Height (1.5 m) (1.5 m) (1.83 m) —The R-value is the reciprocal of the C-value.The C-value <br /> Half Sheets Half Sheets Half Sheets represents thermal conductance and depends on the thickness <br /> of the material. <br /> 0-34' 1 1 1 <br /> (0-10 m) —Thermal Resistance applies to an actual thickness of a material, <br /> and as such is a quantitative physical property that can be used <br /> <200' 35-100' 2 2 2 for determining insulation requirements. <br /> (61 m) (10-30 m) <br /> >100' Formula Calulations:Install half sheet throughout the •Reflectance <br /> (30 m) perimeter and comer region.The width of this region is defined <br /> as the least of the following two measurements:0.1 x building —A measure of the%of solar energy that is reflected away from <br /> >_200' width or 0.4 x building height a surface. <br /> (61 m) any height Note:The minimum perimeter width is 4'(1.2 m).The width is —Dark materials absorb more heat from the sun and can be up <br /> defined as the narrowest dimension. to 70°F(210C)hotter than a reflective white surface given the <br /> same outside temperature and conditions such as wind speed, <br /> location,etc. <br /> The perimeter area,as defined in the above table,may be adhered •Emittance <br /> as an alternative to using half sheets.When adhering the perimeter <br /> area,the number of insulation fasteners must be increased in —A measure of the infrared radiation emitted from a roof surface. <br /> these areas;refer to the insulation attachment section for adhered Unlike reflectance,infrared emissivity may not be affected by <br /> membranes to determine the proper insulation attachment dirt or discoloration of the surface of a material. <br /> pattern.In all cases where the perimeter area is adhered,the <br /> membrane must be mechanically fastened where the perimeter The following references provide useful information regarding <br /> area(the adhered area)meets the field roof area.This attachment energy efficiency: <br /> will prevent pooling of the adhered perimeter area.Refer to the <br /> sheet lay-up details in the mechanically attached system section •ASHRAE Fundamentals Handbook <br /> for requirements on the installation of these half sheets.Note: —Provides detailed design calculations and material energy <br /> When designing for wind loads,ensure that the proper building transfer information utilized by mechanical engineers in the <br /> classification(closed,partially closed,or open)is used if the design of heating,ventilation,and air-conditioning systems. <br /> building has large openings(i.e.,docks with large loading bays, <br /> etc.).Improper classifications can result in roof attachment failure —Suitable for complex energy evaluation considerations such as <br /> caused by designing to lower loads than actually exist for the solar heat gain,exterior shading,total building envelope, <br /> building in question.Factory Mutual Approvals attachment requires building usage,and lighting. <br /> the formula calculations. <br /> Important Note:Most states/jurisdictions have not adopted ASCE ®NRCA Roofing Manual:Architectural Metal Flashing <br /> 7-16.If you are in an area that requires ASCE 7-16,please contact Condensation and Air Leakage Control,and reroofing <br /> GAF for assistance. <br /> —Provides a simplified method for determining the amount of <br /> insulation necessary to construct an energy-efficient low-slope <br /> ENERGY EFFICIENCY roof system. <br /> Thermal transmission standards have been established by building —Provides a simplified method for determining the energy <br /> codes for most buildings.Roof insulation installed above the cost savings resulting from the installation c additional <br /> roof deck is a practical means of achieving the necessary energy roof insulation. <br /> efficiencies.In addition,the use of white-colored reflective —Suitable for most roofing-related energy evaluations. <br /> membranes can reduce the heat load on air conditioning <br /> equipment,as well as provide a moderating effect on the <br /> temperature in proximity to the building. •The NRCA Energy Wise Roof Calculator <br /> —Provides a simplified method for determining the amount of <br /> •U-Value insulation necessary to construct an energy-efficient low-slope <br /> roof system. <br /> —Thermal Transmittance:The number of BTUs(energy) —Provides a simplified method for determining the energy <br /> that pass through a assembly <br /> inI-squar one <br /> our with <br /> sq.m.)sample of cost savings resulting from the installation of additional <br /> a total material assembly in one hour with a temperature roof insulation. <br /> difference between the two surfaces of 1 F(/9 Q. <br /> —Thermal Transmittance applies to an actual total material —Suitable for most roofing-related energy evaluations. <br /> assembly,and as such is a quantitative physical property —Go to www.enerpvise.arca.net <br /> that can be used to represent the overall thermal performance <br /> of a system. <br /> 16 <br />
The URL can be used to link to this page
Your browser does not support the video tag.