My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22643
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22643
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:28:44 PM
Creation date
5/17/2021 2:28:39 PM
Metadata
Fields
Template:
Building Department
Company Name
PEEPLES FAMILY CORP INC
Building Department - Doc Type
Permit
Permit #
20-22643
Building Department - Name
PEEPLES FAMILY CORP INC
Address
38345 5TH AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
70 DESIGN TABLE -RE-COVER-MECHANICALLY ATTACHED <br /> Insulation/Substrate <br /> Attachment Insulation/Substrate Membrane Type <br /> Existing Roofing <br /> System Type Gypsum Wood Fiber/ 3/6 oz VersaShield® Fleece <br /> Mech.Fast. Adhesive/LRF ISO Board Perlite' EPS/XPS Fanfold3 (P ) Solo' None Smooth (FB) <br /> olyma <br /> Smooth Yes Yes' Yes Yes Yes Yes Yes Yes Yes Yes <br /> BUR/IB Yes Yes Yes Yes Yes Yes Yes Yes Yes <br /> Single-Ply Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes? Yes <br /> Membrane Yes Yes' Yes Yes -,Yes Yes Yes Yes Yes <br /> Granule-Surfaced Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes <br /> c BU"IB Yes .Yes4 Yes Yes Yes Yes Yes Yes Yes ; <br /> Gravel-Surfaced Yes Yes4 Yes Yes Yes Yes Yes Yes <br /> BUR/MBS Yes Yes4 Yes Yes Yes Yes Yes Yes <br /> Yes Yes4 Yes Yes Yes Yee Yes <br /> Standing Seam Meta16 <br /> Yes .Yes'..., Yes Yes Yes Yesz Yes. <br /> ' Roof moisture scan required for use of perlite/wood fiber in re-cover roofing systems. <br /> z.An approved cover board is required when XPS Is used as flute fill material. <br /> 3.Fanfold to be used as a re-cover board only. <br /> 4.Low rise foam or hot asphalt can be used for cricket and saddle attachment.If specification requires insulation to be adhered in a mechanically attached system,use foam adhesive designed for <br /> insulation attachment,or hot asphalt. <br /> s.All loose gravel must be removed. <br /> 6.When recovering over an existing standing seam metal roof,fasteners must be directly installed into structural purlins with appropriate fastener type.Fastening into the panel in not permitted. <br /> '.Existing single-ply membrane must be clean,smooth,dry and free of debris. <br />
The URL can be used to link to this page
Your browser does not support the video tag.