ONEMOletc. <br /> #28 Maximum Design Pressure=-67.5 psf: <br /> Deck: APA rated,19/32 CAT,0.578 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having <br /> Jurisdiction. <br /> Base Sheet: Elastobase or Polyglass Base <br /> Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to <br /> the width direction of the sheet. <br /> Spacing: 12-inch o.c.at the 4-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. <br /> Underlayment: Polyflex G,torch-applied. <br /> #29 Maximum Design Pressure=-75 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) <br /> Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat <br /> Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners <br /> Spacing: 10-inch o.c.at the 4-inch wide side laps and 10-inch o.c.at three(3)equally spaced staggered center rows. <br /> Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. <br /> #30 Maximum Design Pressure=-90 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) <br /> Fasteners: Simplex MAXX Cap Fasteners <br /> Spacing: 6-inch o.c.at the 2-inch wide side laps and 6-inch o.c.at two(2)equally spaced staggered center rows. <br /> Underlayment: Elastoflex G TU or Elastoflex 56 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. <br /> #31 Maximum Design Pressure=-90 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Base Sheet: Elastobase(sanded top surface for hot-asphalt or torch-applied cap or poly-film surface for torch-applied cap) <br /> Fasteners: OMG#12 Standard Roofgrip or OMG#14 Heavy Duty with OMG 3"Round Metal Plates or OMG Flat Bottom Metal Plates <br /> Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. <br /> Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or Polyflex G,torch-applied. <br /> #32 Maximum Design Pressure=-90 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Base Sheet: Elastobase(sanded top surface) <br /> Fasteners: Trufast#12 DP or Trufast#14 HD with Trufast 3"Metal Insulation Plates <br /> Spacing: 6-inch o.c.at the 4-inch wide side laps and 6-inch o.c.at three(3)equally spaced staggered center rows. <br /> Underlayment: Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt. <br /> #33 Maximum Design Pressure=-90 psf: <br /> Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. <br /> Base Sheet: Polyglass G2 Base or Polyglass Base(requires use of torch-applied underlayment) <br /> Fasteners: Dekfast#14 with Dekfast Hex plates,OMG#14 HD with OMG 3"Galvalume Steel Plates,OMG Roofgrip#14 with OMG Flat <br /> Bottom Plates(AccuTrac),Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap Fasteners <br /> Spacing: 9-inch o.c.at the 4-inch wide side laps and 9-inch o.c.at four(4)equally spaced staggered center rows. <br /> Underlayment:Elastoflex G TU or Elastoflex S6 G,applied in full mopping of hot asphalt or torch-applied or Polyflex G,torch-applied. <br /> _ #34 Maximum Design Pressure=-90.0 psf: <br /> Deck: APA rated,7/16 CAT,0.418 in.,Exposure 1,OSB sheathing to meet project requirements to satisfaction of Authority Having <br /> Jurisdiction. <br /> Base Sheet: Elastobase or Mule-Hide Nail Base(poly-film top surface) <br /> Fasteners: TRUFAST Versa-Fast Fasteners&Plates with two(2)screws per plate installed 180°into the holes of the plate,parallel to <br /> the width-direction of the sheet <br /> Spacing: 9-inch o.c.at the 2-inch wide side laps and 12-inch o.c.at two(2)equally spaced staggered center rows. <br /> Primer: PG100 or ASTM D41 primer applied to stress plates. <br /> Base Ply: (Optional)Polystick MTS Plus,self-adhered. <br /> Underlayment:Mule-Hide SA-APP Cap Sheet,Mule-Hide SA-APP Cap Sheet(FR),Polyflex SA P,Polyflex SA P FR,Polystick TU Max,Polystick <br /> TU P or Polystick TU Plus,self-adhered. <br /> NENIO ETC,LLC. Evaluation Report P12060.02.09-R25 <br /> Certificate of Authorization#32455 6-EDITION(2017)FBC NON-HVHZ EVALUATION FL5259-929 <br /> Polyglass Roof Underlayments;(954)233-1230 Revision 25:10/14/2019 <br /> Page 10 of 16 <br />