My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22652
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22652
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/17/2021 2:33:59 PM
Creation date
5/17/2021 2:33:58 PM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22652
Building Department - Name
DR HORTON INC
Address
7811 DAVIE RAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 40, BLOCK 9, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> 88.1 <br /> \ <br /> \ <br /> aV�v Q• \ �.P �. G� <br /> TX +s0 GRAPHIC SCALE <br /> QJO�Q 1l0\\\ 0 15 30 <br /> �1''' Q QQyo� \S• 88.7 <br /> .60 <br /> A \ <br /> .r. <br /> g00'y- Cal <br /> l� <br /> SO0' g+oa \/ (REFERENCE BEARING) <br /> n \\ PcA N8930'31-W <br /> 'p SIOe`���� ry `oJ;^'?>0;-/ /IRIGHT OF WAY <br /> I / ��` ;i.?'off:• 'r•Y'`.• ;.._ <br /> FLOOD "AF.F ' :-`•� "� <br /> F.f:=65.i •-s ��oo. •u �z$j,: :•.goy � <br /> SCOT 1 ! O oP <br /> 3g <br /> C 2SDasw� QS �Q <br /> � � O �o <br /> I yo <br /> Curve Table PT <br /> Curve+ Length Radius Delta Chord Bearing Chord <br /> Ci 31.29' 75.00' 235419'. S3022'45'W 31.07' ON LOT CALCULATIONS <br /> C2 79.27' 190.OW 2354'19' N30'&45'E 78.70' LOT = 6,357 SQ. FT. <br /> LIVING AREA = 907 SQ. FT. <br /> C3 78.46' 50.00' B954'38' S45.32'11'W 70.66' GARAGE = 453 SQ. FT. <br /> C4 15.57' 50.00' 1750'44' S09'30'14'W 15.51' ENTRY = 64 SQ. FT. <br /> LANAI = 0 SO. FT. <br /> C5 62.B9' 50.00' 72-03.54' S5427.32-W 58,82' PATIO = 80 SQ. FT. <br /> DRIVEWAY = 438 SO. FT. <br /> A/C PAD = 12 SQ. FT. <br /> WALKWAY = 65 SO. FT. <br /> IMPERVIOUS = 32% <br /> = 2019 SQ. FT. <br /> SOD = 4,338 SQ. FT. <br /> PREPARED FOR: OFF LOT CALCULATIONS <br /> RIGHT OF WAY = 345 SO. FT. <br /> DRIVE APRON = 135 SO. FT. <br /> is fPL+kCR r �'jlc.l'?F PUBLIC S/W - 151 SO. FT. <br /> SOD = 59 SQ. Ff. <br /> TOTALS <br /> BUILDING SETBACKS AREA = 6.702 SQ. FT. <br /> DRIVEWAY = 573 SO. FT. <br /> GARAGE: 25' <br /> FRONT: 2 ' SIDEWALK = 216 SQ. Fr. <br /> REAR: 15, SOD = 4.397 SQ. FT. <br /> SDE- 5' <br /> SIDE STREET: 15' <br /> NOTES: LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS —_— CENTERLINE PC POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING do PT POINT OF TANGENCY <br /> SURVEYING INC.. —--— RIGHT OF WAY LINE RP RADPRC POINTUS OF REVERSECURVATURE <br /> 2 ELEVATIONS ARE BASED ON NAVD 1988 XX.XX PROPOSED ELEVATION PCP PERMANENT CONTROL POINT <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) PERCAL PLAT <br /> ED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF (C) <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PACES OOK <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> THIS IS NOT A SURVEY D&UE DRAINAGE&UTILITY EASEMENT <br /> DE DRAINAGE EASEMENT(PUBLIC) <br /> THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT(PUBLIC) <br /> D&AE DRAINAGE&ACCESS EASEMENT <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F,DATED 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> 19/26/2014,AND FOUND THE SUBJECT PROPERTY APPEARS TO UE IN LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> ZONE-AV',DENOTES AREAS DETERMINED TO BE SPECIAL FLOOD HAZARD OF WAY RESTRICTIONS OF RECORD WHICH <br /> AREAS SUBJECT TO INUNDATION BY THE IX ANNUAL CHANCE FLOOD MAY AftCT THE TITLE OR USE OF THE LAND. <br /> SIT.BASE FLOOD ELEVATIONS DETERMINED TO BE 85.1. THE SURVEYOR <br /> MAKES NO GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> CONTACT THE LOCAL F.E.M.A. AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF DAME 3. NOT VALID WITHOUT THE AUTHENTIC <br /> RAY DRIVE BEING N8930'31'W, PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> (FIELD DATE:) REVISED: <br /> A M E FR I C A N SURVEYOR AND MAPPER FLORIDA LICENSED <br /> SU R V E Y I N G 1, Digitally signed by JamesW. <br /> SCALE 1'- 30 FEET ^ +�..., so Boleman <br /> 8cM A P P I N G INC. �{:e••ti DN:cn=James W.Boleman, <br /> APPROVED BY: .° <br /> JB uu„ � -American Surveying&Mapping, <br /> CERTIFICATION OF AUTHORIZATION NUMBER L.B#6393 3 Inc.,ou=HB, <br /> 3191 MAGUIRE BOULEVARD, SUITE 200 :u;°cm;.•ea" small=JBoleman@asmco po ate.w FOR <br /> JOB No. 190901 LOT 40,BLOCK 9 ORLANDO, FLORIDA 32803 y m,c=U5 THE <br /> 4r..p.' <br /> D <br /> (407) 426-7979 ateaotg.oglato-szso-oaao FIRM <br /> DRAWN BY: D5B PLOT PLAN 09-20-19 KJW WWW.AMER]CMSURVEYINGMDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.