Laserfiche WebLink
r. <br /> 23. Tamper- Resistant Receptacles in accordance with 406.l 1 ofthe 2016 N.E.0 <br /> 24. In accordance with the Land Development Code,lots.shall.be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hot water pipe insulation, <br /> insulation for hot uvater pipe With"a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> folio_wing: <br /> Piping V. inch (19.1 mm)and larger,in nominal diameter. <br /> Piping.serving more than:one dwelling unit. <br /> Piping located outside the conditioned space. <br /> Piping from the water heater to a distribution manifold., <br /> Piping:located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25: Blower.door test shall be provided before C.O: <br /> 26.A copy ofthe energy cacls shall be with pennit at all times <br /> 2Z Copt/of final_insulation report shall be provided with permit before fnaA <br /> 28. No fence,Pool or screen enclosure :is issued with:this Permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O-W--Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />