Laserfiche WebLink
21 Tamper- Resistant.Receptacles in accordance with_ 406.11 of the,2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall.be sodded before final at-least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot.water.'pipe insulation <br /> Insulation for hot water'pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the- <br /> following: <br /> Piping 3j;inch (1.9.1 mm)and larger in.nominal diameter. <br /> Piping serving more than:one dwelling unit. <br /> Piping located outside'tlie conditioned space: <br /> Piping from the.water heater to a distribution manifold. <br /> .Piping.located under a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.O. <br /> 26.A copy of the enemy cacls shall be�with permit at all times- <br /> 27, Conn of final insulation report shall be provided with permit before Thal <br /> 2- No fence, pool or screen enclosure:isissued ivith:thispermit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-.Florida Building Code 6ffi Edition <br /> R.O.W.-Right of Way. <br /> A.D:A,Americans with Disabilities Act N.E.C.-National Electric Code(2016) <br />