Laserfiche WebLink
D <br /> Q <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. F.F.E. shall.be a minimum of 8" above the road elevation and an engineered site plan. <br /> 2: Lots shall be graded to comply with R401.3 of the F.B.C.. <br /> 3:. Compaction test required if 24".or more,of fill,dirt is brought in at any one place. <br /> 4:' Tie in survey required before pouring concrete. <br /> 5: Driveways require.a R.O:W. use permit: All 4 sides of driveway thru the sidewalk shall have <br /> expansion material. <br /> 6: All setbacks shall be met. <br /> 1:. All property markers shall be uncovered--and marked at time of first inspection. <br /> 8: All A:D.A. requirements shall be met: <br /> '.9 No electric,plumbing, mechanical, or.framing shall be;covered without an inspection and <br /> approval first. <br /> 10.. All Garages shall:comply with section R302.6 of the RB-C. (Fire Separation). <br /> 1.1. Appliances,shall not be installed in a location where subject to mechanical damage unless <br /> protected by,approved barriers. M303.4 of the F.B.0 <br /> 12. Water heaters shall comply with section P607.3 of the.F:B:C. <br /> 13. Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308.:1 . <br /> 14: Return air in all bedrooms. F.B.C'. M1620 4 <br /> 1.5. Smoke detectors are to be installed in-accordance with R3111 of.the F.B.C. <br /> 16. All glazing requirements are to bean accordance with R308A o.f the F.B:C: <br /> 17..All means of egress are to be in accordance with R311 of the F.B.C. <br /> 18. "Green.gypsum board" shall riot be used as a backer in showers or tubs:R702.:4.2 F.B.C. . <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI.type breaker. <br /> 20. Carbon monoxide_alarms will be'required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall.be installed in accordance with the F.B.C: <br /> 21. All pluing,inechanical, and electrical shall be separate from unit to unit. This includes all <br /> underground:plumbirm and electric. <br /> 22: All 2016 N.E.C. Codes will be enforced. <br />