Laserfiche WebLink
FORM R405-2017 <br /> FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION <br /> Florida Department of Business and Professional Regulation - Residential Performance Method <br /> Project Name: Elston 2260 Elev G Builder Name: DRH Express Homes <br /> Street: Permit Office: <br /> City,State,Zip: Zephyrhills,FL, SO Permit Number: <br /> Owner: Ae Jurisdiction: <br /> Design Location: FL,Tampa <A County: Pasco(Florida Climate Zone 2 <br /> 1. New construction or existing New(From Plans) 9. Wall Type�s(2478.7 sqft,) Insulation Area <br /> 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2236.00 ft2 <br /> b.Frame-Wood,Adjacent R=1 1.0 242.67 ft2 <br /> 3. Number of units,if multiple family I c.N/A R= ft2 <br /> 4. Number of Bedrooms 4 d.N/A R= ft2 <br /> 5. Is this a worst case? No 10.Ceiling Types (1392.0 sqft.) Insulation Area <br /> a.Under Attic(Vented) R=30.0 1392.00 ft2 <br /> 6. Conditioned floor area above grade(ft2) 2260 b.N/A R= ft2 <br /> Conditioned floor area below grade(ft2) 0 c.N/A R= ft2 <br /> 11.Ducts R ft2 <br /> 7. Windows(216.2 sqft.) Description Area a.Sup:Attic,Ret:2nd Floor,AH:2nd Floor 6 226 <br /> a. U-Factor: Dbl,U=0.34 176.17 ft2 <br /> SHGC: SHGC=0.31 <br /> b. U-Factor: Dbl,U=0.55 40.00 ft2 12.Cooling systems kBtu/hr Efficiency <br /> SHGC: SHGC=0.34 a.Central Unit 33.0 SEER:14.00 <br /> c. U-Factor: N/A ft2 <br /> SHGC: 13.Heating systems kBtu1hr Efficiency <br /> d. U-Factor: N/A ft2 a.Electric Heat Pump 33.8 HSPF:8.20 <br /> SHGC: <br /> Area Weighted Average Overhang Depth: 1.266 ft. <br /> Area Weighted Average SHGC: 0.316 14.Hot water systems <br /> 8. Floor Types (1392.0 ';qft.) Insulation Area a.Electric Cap:50 gallons <br /> a.Slab-On-Grade Edge insulation R=0.0 907.00 ft2 b. Conservation features EF:0.950 <br /> b,Floor over Garage R=19.0 453.00 ft2 None <br /> c.other(see details) R= 32.00 ft2 15.Credits Pstat. <br /> Glass/Floor Area: 0.096 Total Proposed Modified Loads: 77.11 PASS <br /> Total Baseline Loads: 78.04 <br /> I hereby certify that the plans and specifications covered by Review of the plans and <br /> , •. <br /> this calculation are in compliance with the Florida Energy specifications covered by this V <br /> Code. calculation indicates compliance <br /> with the Florida Energy Code. <br /> PREPARED BY: I& Before construction is completed <br /> DATE: this building will be inspected for <br /> compliance with Section 553.908 <br /> I hereby certify that this building,as designed, is in compliance Florida Statutes. <br /> with the Florida Energy Cod <br /> OWNER/AGENT: BUILDING OFFICIAL: <br /> DATE: I DATE: -- <br /> PTA 1? 2 3 e820 <br /> - Compliance requires certification by the air handier unit manufacturer that the air handier enclosure qualifies as <br /> certified factory-sealed in accordance with R403.3.2.1. <br /> -Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an <br /> envelope leakage test report with envelope leakage no greater than 7.00 ACH50(R402.4.1.2). <br /> 11/8/2019 10:16 AM EnergyGauge@ USA 6.0.02(Rev.1)-FlaRes2017 FBC 6th Edition(2017) Compliant Software Page 1 of 5 <br />