Laserfiche WebLink
Manual S Compliance Report Job: <br /> wrightso Date: <br /> Entire House By: <br /> Progressive Air Systems, Inc Plan: Elston 2260 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-816-3399 License:CAC033669 <br /> Project Information, <br /> For: DR Horton <br /> Lot 28 Blk 8 Abbott Park, Zephyrhills, FL <br /> 'Cooling Equipment <br /> Design Conditions <br /> Outdoor design DB: 91.2°F Sensible gain: 24437 Btuh Entering coil DB: 76.4°F <br /> Outdoor design WB: 77.1 OF Latent gain: 3704 Btuh Entering coil WB: 63.3°F <br /> Indoor design DB: 75.0°F Total gain: 28141 Btuh <br /> Indoor RH: 50% Estimated airflow: 1120 cfm <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB036+FB4CNP036 <br /> Actual airflow: 1120 cfm <br /> Sensible capacity: 26281 Btuh 108%of load <br /> Latent capacity: 5022 Btuh 136%of load <br /> Total capacity: 31303 Btuh 111%of load SHR: 84% <br /> fleating Equipment <br /> Design Conditions <br /> Outdoor design DB: 40.0°F Heat loss: 24193 Btuh Entering coil DB: 69.3°F <br /> Indoor design DB: 70.0°F <br /> Manufacturer's Performance Data at Actual Design Conditions <br /> Equipment type: Split ASHP <br /> Manufacturer: Carrier Model: CH14NB036+FB4CNP036 <br /> Actual airflow: 1120 cfm <br /> Output capacity: 30329 Btuh 125%of load Capacity balance: 32 OF <br /> Supplemental heat required: 0 Btuh Economic balance: -99 OF <br /> Backup equipment type: Elec strip <br /> Manufacturer: Model: <br /> Actual airflow: 1120 cfm <br /> Output capacity: 7.5 kW 106% of load Temp. rise: 21 OF <br /> Meets are all requirements of ACCA Manual S. <br /> 2019-Nov-08 10:17:43 <br /> wrightSOfto Right-Suite@ Universal 2017 1T0.21 RSU25554 Page 1 <br /> ...press homes\Elston 3EEB 2260-2nd ft block.rup Cate=MJ8 House Front faces: W <br />