My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22682
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22682
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/20/2021 10:43:15 AM
Creation date
5/20/2021 10:43:13 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22682
Building Department - Name
DR HORTON
Address
7808 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
32
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary Job: <br /> wrightsofto Date: <br /> Entire House BY: <br /> Progressive Air Systems, Inc Plan: Elston 2260 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAGO33669 <br /> Proiect Information: <br /> For: DR Horton <br /> Lot 28 Blk 8 Abbott Park, Zephyrhills, FL <br /> Notes: <br /> Desicln Inform6tion <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 18909 Btuh Structure 18005 Btuh <br /> Ducts 5284 Btuh Ducts 6433 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> PIPT9 0 Btuh <br /> Equipment load 24193 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 24437 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2262 Btuh <br /> Ducts 1442 Btuh <br /> Central vent(0 cfm) 0 Btuh <br /> Heating Coolinri (none) <br /> Area(ft2) 2236 2236 Equipment latent load 3704 Btuh <br /> Volume(ft3) 18914 18914 <br /> Air changes/hour 0.22 0.11 Equipment total load 28141 Btuh <br /> Equiv.AVF(cfm) 69 35 Req. total capacity at 0.75 SHR 2.7 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NBO36 Cond CH14NBO36 <br /> AHRI ref Coil FB4CNP036 <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 11.7 EER, 14 SEER <br /> Heating input Sensible cooling 25200 Btuh <br /> Heating output 34000 Btuh @ 47OF Latent cooling 8400 Btuh <br /> Temperature rise 28 OF Total cooling 33600 Btuh <br /> Actual air flow 1120 cfm Actual air flow 1120 cfm <br /> Air flow factor 0.046 cfm/Btuh Air flow factor 0.046 cfm/Btuh <br /> Static pressure 0.42 in H2O Static pressure 0.42 in H2O <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Capacity balance point=32 OF <br /> Backup: <br /> Input=8 kW, Output=25681 Btuh, 100 AFU E <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> wrightsoft, 201 9-Nov-06 10:17:43 <br /> ACCK Right-Suite®Universal 2017 17.0.21 RSU25554 Pagel <br /> ...press homesXElston 3EE3 2260-2nd if block.rup Cale=MJ8 House Front faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.