Fire Alarm, Systems I�D8130 Door Module <br /> D8130 Door Release Module <br /> www.boschsecurity.com <br /> BOSCH <br /> Invented for life <br /> i ► Two Form C (5 A rated) contacts <br /> Pi °5r`° ► Remotely controls fire system devices <br /> ► Instant or delayed relay activation and restoral <br /> oR b 1 s ao r ► Relay closure follows indicating circuit duration <br /> ► Disable switch supervised for system testing <br /> The D8130 Door Release Module is an accessory for If the user silences the alarm output, the D8130 <br /> fire alarm control panels (FACPs) that controls system contacts deactivate. Latching features must be <br /> functions commonly required in National Fire provided for pilot relays or contactor units requiring <br /> Prevention Association (NFPA) 72 fire alarm control beyond the programmed indicating device time <br /> installations. Two independent Form C dry contacts, or after manual silencing of the indicating circuits. <br /> each rated at 5 A, connect low-voltage circuits to Supervised Disable Switch <br /> magnetic door holders, pilot relays, or contactor units To facilitate fire alarm installation testing, the D8130 <br /> for function control. Module contains a supervised disable switch that <br /> Typical applications are: prevents operation of the relay contacts. An amber <br /> • releasing fire doors, emergency exit doors, and Disable LED indicates when the switch is in the <br /> stairwell doors elevator recall disable position. Connect one or more D8130 modules <br /> • <br /> • HVAC control to any unused 1 kQ zone or point of the control panel <br /> to detect module disabling. <br /> Functions A trouble is indicated when the D8130 switch is in the <br /> disable position, and a restoral signal is sent when the <br /> Contact Activation switch is returned to the normal position. (Refer to the <br /> The control panel indicating output activates the control panel's Program Entry Guide for details on <br /> contacts of the D8130. A red Alarm Input LED programming a trouble signal for an open or short <br /> indicates contact activation. condition.) When the contacts are activated with the <br /> The duration of the contact activation follows the switch in the normal position, no trouble indications <br /> programmed indicating circuit time. Use a jumper to are sent to the control panel. <br /> set the contact activation to be instant or delayed by <br /> 14 sec when there is an alarm condition. With the Release Contact Outputs <br /> delay option selected, a 14 sec delay also occurs upon A normally-open (NO) terminal, a normally-closed (NC) <br /> restoral. This delay feature is useful for momentary terminal, and a common (COM) terminal are provided <br /> bell tests. for each D8130 contact. In the inactive state of the <br /> contact, the NC terminal has continuity with the COM <br /> terminal. In the active state of the contact, the NO <br /> terminal has continuity with the COM terminal. <br />