Laserfiche WebLink
D9"127 Series PIOPIT Moddles <br /> Region Certification D8125 to POPIT Loops; Use one two-wire data expansion loop, or distribute <br /> I CSFM see our website the POPITs on up to three loops. The maximum <br /> FDNY 6059[D9412GV3&D7412GV3] lengths shown in the following table are for all data <br /> CoA expansion loops combined connected to the same <br /> -- - - - - D8125 module. Setting DIP switches on the POPIT <br /> FDNY- 6174 modules assigns them to point numbers. The switch <br /> CoA <br /> setting on each POPIT assigns it a point number, <br /> FDNY- 6196 regardless of its physical location. <br /> CoA <br /> POPIT to Sensor Loops <br /> Australia j CTICK C-Tick The number of detection devices each sensor loop can <br /> Canada ULC AMCX7.S1871-Central Station Alarm supervise is limited only by the resistance on the loop. <br /> Units Certified for Canada Resistance on each sensor loop must be less than <br /> ULC AOTX7.S1871 Local Alarm UnitsCerti 100 O not including the end-of-line (EOL) resistor. <br /> fied for Canada Certain UL and National Fire Protection Association <br /> ULC APAW7.S1871 Police station connec (NFPA) applications can limit the number of detection <br /> tedAlarm Units Certified for Canada devices. Consult the appropriate UL or NFPA <br /> standards. <br /> ULC APOUTS1871 Proprietary Alarm Units Terminate each POPIT sensor loop with the 33 kO EOL <br /> I Certified for Canada resistor included with each POPIT. <br /> ULC NBSX7.S1871 Household Burglar Alarm Use a twisted-pair wire (six twists per foot) in all <br /> _ System Units Certified for Canada POPIT installations for both the data expansion loop <br /> Installation/con. fig4ration notes wiring and the POPIT sensor loops. Run wires away <br /> from AC sources to prevent AC induction. <br /> Compatibility Information Parts iincluded <br /> Control Panels All G Series control panels,D9412,D7412, <br /> D7212,D7212131,D9112,D9112131, Quantit Component <br /> D8112131,D8112G2,and D9124 Y <br /> Module D8125 1 POPIT module <br /> The D8125 Multiplex Zone Expander is required. The 1 33 kQ EOL resistor <br /> D9127 modules are wired in parallel on the D8125 <br /> 1 Magnet(D9127T only) <br /> data loop. <br /> Number of POPIT Modules per Control Panel 1 Hardware pack <br /> D7212G,D7212GV2,D7212GV3 32.D9127 POPITs 1 Literature pack <br /> D7212131 40 D9127 POPITs Technical specifications <br /> D7212,D7412,D7412G,D7412GV2, 67 D9127 POPITs Environmental Considerations <br /> D7412GV3 ; -- -- --�—- — <br /> - <br /> Relativehumidity I ,Up to93%non-condensing <br /> D9124 119 D9127 POPITs — -- --- " .. - - -- - -- - - - <br /> Temperature 0°C to+50°C(+32°F to+122°F) <br /> D9112B1 126 D9127 POPITs (operating) <br /> D9112,D9412,D9412G,D9412GV2, 238 D9127 POPITs Properties J y- <br /> D9412GV3 _�-------- -------__-�_-_ <br /> Color Off white <br /> Wiring Considerations -- --------- ! - - - ---,- - - <br /> Dimensions 8.1 cm x 3.8 cm x 2.4 cm <br /> Wire Size Maximum Length of all Data <br /> (3.2 in.x 1.5 in.x 0.9 in.) <br /> Expansion Loops Combined <br /> 0.8 mm(22 AWG) 549 m(1800 ft) Material I UL Listed fire-resistant _- <br /> 1.0 mm(20 AWG) 881 m(2890 ft) <br /> 1.2 mm(18 AWG) 1402 m(4600 ft) <br /> 1.5 mm(16 AWG) 2231 m(7320 ft) <br /> 1.8 mm(14 AWG) 3551 m(11650 ft) <br />