Laserfiche WebLink
'PBR' PANEL ALL STEEL BUILDINGS LACE 1—14 R 1 1/4'SCREW <br /> IN EVERY FLAT FOR THE <br /> SCREW DOWN PATTERN AND PLACE L I 12%3/4' STITCH INTERMEDIATE RUNS. <br /> PLACE SCREWS EVERY <br /> SCREW N THE PANEL LAP 76.O.C.(HA%INUI°. <br /> PROJECT: COMPONENTS, INC. EVERY ID' TO 24 <br /> 10159 U.S. HWY. 41 SOUTH TYPICAL VALLEY ° ° ° <br /> GIBSONTON, FL. 33534 DETAIL RAX <br /> PH # 813-671-8044 SEALANT VALLEY 0 0 0 L. <br /> 166MPH ult/o sd/130o sd ROOF SLOPE FAX # 813-671-8602 MOISTURE BARRIER <br /> (3 SEC, GUST) FBC 2014 CHANGE 'PBR'/'R' PANEL (BY OTHERS) G 0 0 0 <br /> 5 T H EDITION PBR'/'R' PANEL MOISTURE BY OTHERS)IER WOOD SCREW to, <br /> PRODUCT APPROVAL 102 WOOD 0 <br /> # FL4525,5 & ,6 GRIP SCREW <br /> OR EQUIVALENT ° <br /> ° ° Q It ° ° <br /> UBSTRA <br /> NOTE: TRANSITION TRIM D PLACE 2—14 R 1 1/4•SCREV <br /> ROOF PANEL MAY PLYWOOD SUBSTRATE IN EVERRY FL EAVE AT <br /> PALONG THE <br /> OVERHANG THE EAVE A 14XSUBSTRATE PHR'/'R' PANEL <br /> MAXIMUM OF 4 INCHES. NOTE: ROOF AREAS WITH A PITCH CHANGE RIP WOOD <br /> BETWEEN 170 & 180 DEG. SHALL BE 14 <br /> GRIP SCREW <br /> COVERED BY ONE CONT. PANEL (NO MOISTURE BARRIER <br /> TRANSITION FLASHING REQUIRED). (BY OTHERS) I' X 4' WOOD <br /> NOTE: RUNNERS <br /> ROOF PANEL MUST �1ONG—U% 7/8 NEW IOX3 DECK RUNNERS <br /> HAVE A MINIMUM PLYWOOD LONG—UFE UIPTEK — SCREW or 3' RING <br /> SUBSTRATE SHANK NAIL. <br /> Y2:12 ROOF SLOPE. (USED TO SECURE 1j <br /> WOOD RUNNER) <br /> FIELD KNOTCH RIGID BOARD <br /> TRANSITION TRIM INSULATION <br /> 26 GA. 'PBR' PANEL 14 X 1 1/4' SCREW NOTE: (OPTIONAL). <br /> FIELD KNOTCH TRANSITION TRIM <br /> AROUND HIGH OF PANEL, MASTIC & NEW/EXIST. <br /> CLOSURES ARE OPTIONAL. PLYWOOD <br /> SUBSTRATE OR IN III ltmF Imp <br /> TORCH DOWN OR ` <br /> SHINGLES COVERED }I <br /> NEW IOX3 DECK BY 30 LB. FELT <br /> SCREW OR 3' RING (FELT IS NEW/EXISTING <br /> NEW I'X4' WOOD RUNNERS SHANK NAIL. OPTIONAL), ROOF TRUSS <br /> TYP. PANEL LAP (OPTIONAL) I HEREDY CERTIFY THAT 114AVC D.W. SMITH, PE, # 53608 <br /> REVIEWED THIS PLAN AND FIND IT TO FLORIDA PRDYESSI°aL ENGINIR L=4C HOMER 33608 <br /> 12 X 3/4' SCREW HE IN NEW/EXISTING PLYWOOD SUBSTRATE THE FLORIDA DSUILIOING CODE 2011ANCE WITH E3TH1EDITION PROJECTS ENGINEERING CONSULTANT <br /> ELASTOMERIC TAPE (OPTIONAL) (PANEL CAN BE APPLIED OVER ssw WAII.AStta1 NUVE- M QTA,rLMIM oasas <br /> SHINGLES (MAX. ONE LAYER) MOE#2SR-M-430 fUt 32-sat-M7 E-01U enfWlee rV r l <br /> SHINGLES/PLYWOOD MAY BE COVERED <br /> V ult DESIGN PRESSURE FROM RISK CATEGORY I MAP BY 30 LB. FELT (FELT IS OPTIONAL). <br /> HAVE BEEN CONVERTED TO Vasd PER FBC 1609.3.1 EQ'N 16-32 2��7 DAVID V,SMITH PE,M53608 & ' <br />