Laserfiche WebLink
23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N..E:C <br /> 24. In accordance with the Land Development Code,lots,shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25-. R403.5.3Hot water pipe insulation <br /> Insulation for hot.water pipe With'a minimum thermal resistance (R-value) of R-3 shall.be applied to the <br /> foll6Wing: <br /> Piping 3h inch (1.9.1 mm) and larger in nominal,diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space.- . <br /> -Piping!from the:water heater to a distribution manifold: <br /> Piping located under.a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25.Blower.door test shall be provided before C.O: <br /> 26.A copy of the enerFy cacls shall be with permit at all times. <br /> 27. Copv of final insulation report-shall be provided with permit before rinaL <br /> 28.No knee,pool or screen enclosure-.is issued with this Permit. <br /> F.F.E.-Finished Floor Elevation <br /> F.B.0 .:Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />