Laserfiche WebLink
Y i <br /> 23. Tamper- Resistant Receptacles in accordance with 406.11 of the 2016 N.E.C' <br /> 24. In accordance with the Land Development'C.ode,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. R403.5.3Hot water pipe insulation <br /> Insulation for hot water pipe with a minimum thermal resistance (R-.value) of R-3 shall be. applied to the <br /> following: <br /> Piping V, inch (19.1 mm) and larger in nominal diameter. <br /> Piping serving more than one dwelling unit. <br /> Piping located.outside the conditioned space.. <br /> Piping from the water-heater to a-distribution manifold-,, <br /> Piping:located under a floor slab. <br /> Buried in piping, <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower:door test shall be provided beffore C.O: . <br /> 26. A copy of the energy cacls shall be with permit at all tunes. <br /> 2z Copy of final insulatioiz re,06rt shall be provided ivith permit before fnaL <br /> 28. No fence,-Pool or screen enclosare :is issued_with this.permit <br /> F.F.E.-.Finished Floor Elevation <br /> F.B.C- Florida Building Code.6t`Edition <br /> R.O.W.-Right of Way. <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />