Laserfiche WebLink
23: Tamper-Resistant.Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. In accordance with the Land Development Code, lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25: R403.5.3Hotwater.pipe insulation. <br /> Insulation for hot v►rater'pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following:.-.. <br /> Piping 3/, inch (19:1 mm)and larger in.nominal diameter. <br /> Piping serving more than-one dwelling unit. <br /> Piping located outside the conditioned space.. <br /> Piping from the:water�heater to a distribution manifold:, <br /> ,Piping:located under'a floor slab: <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems: <br /> 25.Blower door test shall be provided before C.O: <br /> 26.A copy ofthe energy eacls shall be with permit at all dines <br /> 27. Copy of final insulation report shall be provided with permit before foal <br /> 28.No fence, pool or screen enclosure :is issued with:th is.permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C-Florida Building Code Oh Edition <br /> R.O.W.-Right of Way <br /> A.D.A.-Americans with Disabilities Act N.E.C.-National Electric Code (2016) <br />