My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22773
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22773
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:07:17 AM
Creation date
6/15/2021 10:07:17 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22773
Building Department - Name
DR HORTON INC
Address
8008 WHEAT STONE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
13
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 7, BLOCK 1, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> ON LOT CALCULATIONS <br /> LOT = 6,250 SO. FT. <br /> LIVING AREA = 2,034 SO. FT. <br /> GARAGE = 458 SQ. FT. <br /> ENTRY = 28 S0. FT. <br /> LANAI = 218 SQ. FT. <br /> ENTRY SLAB = 23 SQ. FT. <br /> DRIVEWAY - 432 SQ. FT. <br /> A/C PAD = 12 SQ. FT. <br /> WALKWAY = 36 SO. FT. n <br /> IMPERVIOUS = 52% <br /> = 3241 SQ. FT. <br /> SOD = 3.009 SQ. FT. i <br /> OFF LOT CALCULATIONS <br /> RIGHT OF WAY = 650 SO. FT. 1" = 30' <br /> DRIVE APRON - 152 SQ. FT. GRAPHIC SCALE <br /> PUBLIC S/W = 250 SO. FT. 0 15 30 <br /> SOD - 24B SO. FT. <br /> TOTALS <br /> AREA = 6,900 SO. FT. <br /> DRIVEWAY = 584 SO. FT. <br /> SIDEWALK = 286 SO. FT. <br /> SOD = 3,257 SO. FT. <br /> ZEPHYRHILLS SMALL FAMRS <br /> PB4. PG29to <br /> i <br /> 6�A » , s� S89a47'OOaE N <br /> S89-47 00 E 125.00 —25.00 _ <br /> 5' D&AE , — —�,m Q <br /> O 28.0' 59.8LIS ' 27.8'•I i <br /> O < o <br /> lf) �I*w <br /> n Y• PROPOSED 11.ID=tz <br /> I law <br /> d E—eNo15• OL L UIl dw MODEL A4DB 5.0 <br /> =Q <br /> 2 <br /> Lyl C � ZP <br /> OOO. 27.0 <br /> NIt 'LOR oJ JI <br /> O ON-88.70' Q <br /> OU Ix 9.3' o oo. <br /> aLd <br /> : LU <br /> 7a.00' <br /> O A/c 0Z •28i0 . 70.0 <br /> LLI <br /> iV p <br /> iV 27.0' N <br /> 5' D&AE <br /> 8j9 N89"47�00"W 125.00 C 6� <br /> 6 <br /> 125.12-(P) $ I a <br /> FLOOD ZONE"Xa <br /> APPROXIMATE DELINEATION LINE,/ O m <br /> SCALED FROM FEMA MAP. I <br /> FLOOD ZONE 'AE' \ <br /> PREPARED FOR: <br /> D'HI'HOIBON° <br /> WRT— <br /> BUILDING SETBACKS <br /> FRONT: 22' <br /> GARAGE: 27' <br /> REAR: 13' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING k — - — CENTERUNE PT POINT OF TANGENCY <br /> SURVEYING INC.. ———— RIGHT OF WAY LINE RP RADIUS POINT <br /> PRC POINT OF REVERSE CURVATURE <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION <br /> ENT CONTROL POINT <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) L <br /> PLAT <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF 0 (c) CALCULATED <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES ooK <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> THIS IS NOT A SURVEY DEAF DRAINAGE EASEMENT EASEMENT <br /> THIS IS A PLOT PLAN ONLY UE UTILITY EASEMENT(PUBLIC) <br /> FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M.MAP NO.12101CO293F• SURVEYOR NOTES: <br /> DATED 09/26/20K AND FOUND THE SUBJECT PROPERTY APPEARS TO UE 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> PARTIALLY IN ZONE'X&Ar.ZONE"X'.AREAS DETERMINED TO BE TES LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> AREAS OUTSIDE THE <br /> TO BE SPECIAL FLU HAZZARDZAREA WBJECT TO OF WAY, RESTRICTIONS OF RECORD WHICH <br /> INUNDATION BY THE IX ANNUAL CHANCE FLOOD EVENT,BASE FLOOD MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> ELEVA71ONS DETERMINED TO BE 86.6.THE SURVEYOR MAKES NO <br /> GUARANTEES AS TO THE ABOVE INFORMATION.PLEASE CONTACT THE LOCAL2IFICATIO <br /> FOR . NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF WHEAT 3. NOT VALID WITHOUT THE AUTHENTIC <br /> STONE DRIVE BEING NOO13'0o'E:PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> A M E R I CA N ELECTRONIC <br /> ANDAMA P A�FLORIDA LICENSED <br /> (FIELD DATE:) REVISED: <br /> ,--3D FEET S U fp�V CC Y 1 N G Digitally signed by,ames W. <br /> SCALE: <br /> $e M AP P I N G INC. ^� DN:cn=James W.Boleman, <br /> APPROVED BY: `9 w. -Amerian Surveying&Mapping, <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB#6393 — Inc,ou=H6, FOR <br /> 190901 LOT 7,BLOCK 1 3191 MAGUIRE BOULEVARD, SUITE 200 fs email=lboiemanPa-corpate.com THE <br /> JOB NO. ORLANDO. FLORIDA 32803 p's;:r• c=us FIRM <br /> (407) 426-7979 Dare:2020.02261etut1-05'OW <br /> DRAWN BY. RMB 25-20 JSO WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE <br /> PLOT PLAN D2— <br /> I <br /> I <br /> I <br />
The URL can be used to link to this page
Your browser does not support the video tag.