Laserfiche WebLink
5;� D <br /> Q i � <br /> F I �IIfl <br /> v <br /> R <br /> Single Family Dwelling <br /> Plan Review Comments <br /> 1. RRE.. shall.be a minimum of 8" above the road elevation-and an engineered site plan. <br /> 2. .Lots shall be graded to comply with R401.3 of the F.B.C.- <br /> 3. Compaction test required if 24" or more of fill dirt is brought in at any one place. <br /> 4: Tie in survey required before pouring concrete. <br /> 5. Driveways require.a R.O:W. use permit. All 4 sides of driveway thru the sidewalk shall have <br /> expansion material.. <br /> 6. All setbacks shall be met. <br /> 7. All.property markers shall be uncovered and.marked at time of first inspection. <br /> 8: All A:D.A.requirements shall be met: <br /> 9. No electric,plumbing,mechanical, or framing shall.be covered without an inspection.and . <br /> approval first. <br /> 10.All Garages shall comply with section R302.6 of the F.B.C. (Fire Separation). <br /> . . <br /> 11. Appliances shall not be installed in a location.where subject to mechanical damage unless <br /> protected by approved barriers. M303:4 of the F.B-.0 <br /> 12. Water heaters shall comply with section P607.3 of the F.B.C. . <br /> 13.Foundation supports for A/C units shall be raised at least 3" above finished grade. M1308:1 <br /> 14. Return air in all bedrooms. F.B.C.. M16204 <br /> 15. Smoke detectors are to be installed in accordance with R3.13-.1 of.the F.B.C. <br /> 16.All glazing requirement are to be in' accordance with R308.4 of the F.B.C. <br /> 17. All means of egress are to be in accordance with R31 I of the F.B.C.'. <br /> 18. "Green gypsum.board" shall riot.be used as a backer in showers or tubs. R702.4.2 F.B.C. <br /> 19. Combination-type AFCI breakers are required at all locations requiring an AFCI type breaker. <br /> 20. Carbon monoxide alarms will be required in new construction that uses fossil-burning heating <br /> or appliances or an attached garage. They shall be installed mi accordance with the F.B.C. <br /> 21. All plumbing,mechanical, and electrical shall be separate from unit to unit: This includes all <br /> underground:plumbing and electric. <br /> 22. All 2016 NX.C. Codes will be enforced. <br />