My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22779
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22779
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:11:35 AM
Creation date
6/15/2021 10:11:32 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22779
Building Department - Name
DR HORTON INC
Address
7796 DAVIE RAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Project Summary Job: <br /> -f - wrightsoft Enfire House Y Bye: <br /> Progressive Air Systems, Inc Plan: Roble2447 <br /> 5907 Dasher Ct,Port Richey,FL 34668 Phone:727-847-3898 Fax:727-815-3399 License:CAC033669 <br /> ® • • • <br /> For: DR Horton <br /> Lot 11 Blk 10 Abbott Park, Zephyrhills, FL <br /> Notes: <br /> it ' • • • <br /> Weather: Tampa Intl AP, FL, US <br /> Winter Design Conditions Summer Design Conditions <br /> Outside db 40 OF Outside db 91 OF <br /> Inside db 70 OF Inside db 75 OF <br /> Design TD 30 OF Design TD 16 OF <br /> Daily range L <br /> Relative humidity 50 % <br /> Moisture difference 54 gr/lb <br /> Heating Summary Sensible Cooling Equipment Load Sizing <br /> Structure 17808 Btuh Structure 19500 Btuh <br /> Ducts 7018 Btuh Ducts 9333 Btuh <br /> Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh <br /> (none) (none) <br /> Humidification 0 Btuh Blower 0 Btuh <br /> Piping 0 Btuh <br /> Equipment load 24826 Btuh Use manufacturer's data y <br /> Rate/swing multiplier 1.00 <br /> Infiltration Equipment sensible load 28833 Btuh <br /> Method Simplified Latent Cooling Equipment Load Sizing <br /> Construction quality Semi-tight <br /> Fireplaces 0 Structure 2693 Btuh <br /> Ducts 1786 Btuh <br /> Central vent (0 cfm) 0 Btuh <br /> Heating Cooling (none) <br /> Area(ft2) 2423 2423 Equipment latent load 4479 Btuh <br /> Volume(ft3) 19380 19380 <br /> Air charges/hour 0.22 0.11 Equipment total load 33312 Btuh <br /> Equiv.AVF(cfm) 71 36 Req. total capacity at 0.75 SHR 3.2 ton <br /> Heating Equipment Summary Cooling Equipment Summary <br /> Make Carrier Make Carrier <br /> Trade CARRIER Trade CARRIER <br /> Model CH14NB042****A Cond CH14NB042****A <br /> AHRI ref Coil FB4CNF042L <br /> AHRI ref <br /> Efficiency 8.2 HSPF Efficiency 11.0 EER, 14 SEER <br /> Heating input Sensible cooling 30750 Btuh <br /> Heating output 38500 Btuh @ 47OF Latent cooling 10250 Btuh <br /> Temperature rise 26 OF Total cooling 41000 Btuh <br /> Actual air flow 1367 cfm Actual air flow 1367 cfm <br /> Air flow factor 0.055 cfm/Btuh Air flow factor 0.047 cfm/Btuh <br /> Static pressure 0 in H2O Static pressure 0 in H2O <br /> Space thermostat Load sensible heat ratio 0.87 <br /> Capacity balance point=29 OF <br /> Backup: <br /> Input=7 kW, Output=24633 Btuh, 100 AFUE <br /> Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. <br /> ACC -F - wrightsoft" Right-Suite®Universal 2017 17.0.21 RSU25554 2020-Mar-16 13:13:18 <br /> Page 1 <br /> ...ghtsoit Files\Express homes\Roble 3EFB 2447.rup Calc=MJB House Front faces: W <br />
The URL can be used to link to this page
Your browser does not support the video tag.