Laserfiche WebLink
23. Tamper-Resistant Receptacles in accordance with 406.11 of the 2016 N.E.0 <br /> 24. Ih accordance with the Land Development Code, lots,shall.be soddedbefore_ final at least 10 <br /> feet around-the structure: <br /> 25:-.R403.5.3Hot Water pipe insulation <br /> Insulation for.hot.water'pipe With'a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping:/:inch (19.1 mm) and largerin:nominal diameter: <br /> Piping serving more than one dwelling unit. <br /> Piping located outside the conditioned space:. <br /> Piping from the**ter heater to a distribution manifold., . <br /> Piping:located under'a floor slab. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25. Blower door test shall be provided before C.Q. <br /> 26.A copy of the enerzy cacls shall be with permit at all times- <br /> 27 Copy of finalinsuladon report shall be provided ivith permit before finch . <br /> 28:No fence, pool or screen enclosure :is issued with ahis permit <br /> F.F.E.-Finished Floor Elevation . <br /> F.B.0 •Florida Building Code 6a'Edition <br /> R.O.W.-Right of Way- <br /> A.D.A.-Americans with Disabilities Act_ N.E.C.-National Electric Code(2016)= <br />