Laserfiche WebLink
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 7, BLOCK 10, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 213, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> PI <br /> Line Table <br /> Linea Direction Length <br /> O I L1 S0034'52•W I50.00' �< <br /> LOT 8 I =3 <br /> U BLOCK 10 I 0Io <br /> _j w� I <br /> m eti S89.25'08" , 9�e N8975'OB'W I 0 GRAnPHI C SCALE <br /> E 115.00 25.00 <br /> s'D&AE ' " ?I :r,;-- .. --� 0 15 30 <br /> -----� — <br /> n <br /> Q ----31.8'----., -------------— 25.5--- <br /> " 57.7 33' W <br /> O *< cLd <br /> No 1{'�1 <br /> W <br /> 4 � NII z O <br /> —1—I m' or 0.m .00 QO <br /> O 48.7 <br /> Z h5D&AE m0 <br /> N89'25'08"W 115.00' W <br /> �m <br /> o LOT 6 I Sb <br /> BLOCK 10 I lyW <br /> F V <br /> OO <br /> m <br /> PI' <br /> ON LOT CALCULATIONS _------- -----_ <br /> LOT = 5,750 SO. FT. PLAT BOUNDARY <br /> LIVING AREA = 1,672 SO. FT. <br /> GARAGE — 432 SO. FT. <br /> ENTRY = 38 SO. FT. <br /> LANAI = 96 Sp. FT. <br /> PATIO = 0 Sp. FT. <br /> DRIVEWAY = 408 S0. FT. <br /> A/C PAD = 12 S0. FT. <br /> WALKWAY = 28 SO. FT. <br /> IMPERVIOUS = 479E <br /> = 2686 SO. Fr. <br /> SOD = 3.064 SQ. FT. <br /> OFF LOT CALCULATIONS <br /> RIGHT OF WAY = 600 SQ. Fr. <br /> PREPARED FOR: PUBLIC S/W = 250 sa. FT. <br /> SOD = 217 S0. FT. <br /> B-11-HOWN'N TOTALS <br /> AREA = 6,350 SO. FT. <br /> DRIVEWAY — 541 SO. FT. <br /> BUILDING SETBACKS SIDEWALK = S . FT. <br /> 3,2 <br /> SOD = 81 SQ. FT. <br /> FRONT: 20• <br /> GARAGE: 25' <br /> REAR: 15' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — BUILDING SETBACK LINE Pl POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC PONT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING & — CENTERLINE PT POINT OF TANGENCY <br /> SURVEYING INC.. ——— — RIGHT OF WAY LINE RP RADIUS POINT <br /> PRC POINT OF REVERSE CURVATURE <br /> 2. ELEVATIONS ARE BASED ON NAVD 198E PROPOSED ELEVATION PCP PERMANENT CONTROL POINT <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (C) CALCULATEDONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF ( ) <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGE OOK <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SQ. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. - F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> THIS IS NOT A SURVEY Dd:UE DRAINAGE&UTILITY EASEMENT <br /> DE DRAINAGE EASEMENT(PUBLIC) <br /> UE UTILITY EASEMENT(PUBLIC) <br /> THIS IS A PLOT PLAN ONLY D&AE DRAINAGE&ACCESS EASEMENT <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F. 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> APPEARS TO LIE IN ZONE 'X', AREAS DETERMINED TO BE OF WAY, RESTRICTIONS OF RECORD WHICH <br /> OUTSIDE THE 0.2X ANNUAL CHANCE FLOODPLAIN. THE MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. LOCATED EXCEPT AS SHOWN. ' <br /> AGENT FOR VERIFICATION. ' <br /> BEARING BASIS: A!5hA 3. NOT VALID WITHOUT THE AUTHENTIC <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF BROAD ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> POINTE DRIVE BEING SGDB4'52'W PER PLAT. A M E.R 1 CA N ELECTRONIC <br /> LECTR O II SEALND M OF A FLORIDA LICENSED <br /> (FIELD DATE:) REVISED: <br /> 1' 3D FEET S U RV EY 1 N G ag° �"y° Digitally signed by JamesW. <br /> SCALE Q a,.ri Boleman <br /> CX MAPPING INC. a� +j` �" a DN:cn=James W.Boleman, <br /> APPROVED BY: `B r-w„ o=American Surveying&Mapping, <br /> CERTIFICATION OF AUTHORIZATION NUMBER L13a6393 .•�F� ``In<-ou=HB, <br /> 3191 MAGUIRE BOULEVARD, SUITE 200 y„^ r>' email=lBaleman@asmcorpo ate.mm FOR <br /> 190901 LOT 7,BLOCK 10 e/mniwnn %,r Date:2019.09.241635:40-04'00' THE <br /> JOB NO. ORLANDO, FLORIDA 32803 m`°""° FIRM <br /> THE <br /> (407) 426-7979 DATE DRAWN BY: O58 PLOT PLAN 09-20-19 ZA WWW.AMERICANSURVEYINGANDMAPPING.COLT JAMES W.,'BOLEMAN PSM# 6485 <br />