21 Tamper- Resistant.Receptacles in accordance with 406.11 of the 201. N.E:C <br /> 24. In accordance with the Land Development Code,lots shall be sodded before final at least 10 <br /> feet around the structure. <br /> 25. 14403.5.3Hot.water.'pipe insulation. <br /> Insulation for hot water pipe with a minimum thermal resistance (R-value) of R-3 shall be applied to the <br /> following: <br /> Piping ,!.inch (19.1 mm)and larger in nominal diameter.. <br /> Piping serving more than one dwelling unit. <br /> Piping located.outside the conditioned space. <br /> Piping from the waterheater to a distribution manifold. <br /> Piping:located under a floor slab.. <br /> Buried in piping. <br /> Supply and return piping in recirculation systems other than demand recirculation systems. <br /> 25:Blower,door test shall be provided.before C.O: <br /> 26. A cove of the energy cacls shall be with permit at all times <br /> 27. Copu of that insulation report-tshall be provided ivith permit before LlnaL <br /> 28:No fence.-pool or screen enclosure :is issued with this permit <br /> F.F.E.-Finished Floor Elevation <br /> F.B.C- Florida Building Code 6t'Edition <br /> R.O.W.-Right of Way. . <br /> A.D.A.-.Americans with Disabilities Act . N.E.C.-National Electric.Code (2016) <br />