My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22784
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22784
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:14:32 AM
Creation date
6/15/2021 10:14:31 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22784
Building Department - Name
DR HORTON INC
Address
7771 DAVIE RAY DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
11
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 35, BLOCK 9, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> ON LOT CALCULATIONS <br /> LOT = 5,750 SO. FT. <br /> LIVING AREA = 1.672 SQ. FT. <br /> GARAGE = 432 SQ. FT. <br /> ENTRY = 38 SQ. FT. <br /> LANAI = 96 S0. FT. <br /> PATIO - 0 SO. FT. <br /> DRIVEWAY = 408 SO. F. <br /> A/C PAD = 9 SO. F. <br /> WALKWAY = 28 SO. FT. <br /> IMPERVIOUS = 47% <br /> = 2683 SQ. FT. a <br /> SOD = 3,067 SO. FT. <br /> OFF LOT CALCULATIONS <br /> RIGHT OF WAY = 650 SO. FT. Z <br /> DRIVE APRON = 152 SO. FT. 1" = 30' <br /> PUBLIC S/W = 250 SQ. FT. I GRAPHIC SCALE <br /> SOD - 248 SO. FT. 0 15 30 <br /> TOTALS <br /> AREA = 6,400 SQ. FT. <br /> DRIVEWAY = 560 SO. FT. <br /> SIDEWALK = 278 SQ. FT. <br /> SOD = 3,315 SO. FT. <br /> J <br /> o� <br /> ?�,aY' V <br /> nc'O5 �P O c� a <br /> Oq � <br /> Q�3' <br /> lr' 00 1 <br /> —'m I <br /> MI <br /> S89'25'08"E 115.00' 8j's 1 582 �E 0 <br /> W <br /> �? ----3i,g'•---. ------ 5' ------ -- - -'25.51--- O 3 <br /> m 57.7 O "� w <br /> <m O I A/C 58.33 o <br /> U W W. <br /> UJ ii W N -7 PROPOSED <br /> ' ,- e 't10.7 <br /> ` <br /> a <br /> ARIA <br /> UmW 4EAB- C g7 . NQU <br /> Ln U ED <br /> to <br /> nz ELEVATION-89.50'. LO0 , 7. .Bi Ha <br /> FLOOR <br /> KOaZQ m I <br /> azO ol Qw <br /> ir 013< O 1 o O13 Z -31.8.--- 4 ------ .5I O b <br /> ui 5' D&AE U) L 1n <br /> 5'08"W 115.00' <br /> 0�99 I <br /> rn I <br /> PREPARED FOR: <br /> 0'41°N0fiNN*I m a <br /> BUILDING SETBACKS <br /> FRONT: 20' <br /> GARAGE: 25' <br /> REAR: 15' <br /> SIDE: 5' <br /> SIDE STREET: 15' <br /> NOTES: LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE — — — BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC PONT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING & - - - CENTERLINE PT POINT OF TANGENCY <br /> SURVEYING INC.. —-- — RIGHT OF WAY UNE RP RADIUS POINT <br /> PRC POINT OF REVERSE CURVATURE <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 XX.XX PROPOSED ELEVATION PCP PERMANENT CONTROL POINT <br /> DATUM. TYP TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE (P) PER PLAT <br /> (C) CALCULATED <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF A/c AIR CONDITIONER PB PLAT BOOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR FOS PAGES <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.EM.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE RATE MAP <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> THIS IS NOT A SURVEY DEUE DRAINAGE EASEMENT EASEMENT <br /> THIS IS A PLOT PLAN ONLY UE UTIUTY EASEMENT(PUBLIC) <br /> FLOOD NOTE: I HAVE EXAMINED THE F.I.R.M.MAP No.12101CO293F, SURVEYOR NOTES: <br /> DATED 09/26/2014,AND FOUND THE SUBJECT PROPERTY APPEARS TO 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> UE PARTIALLY IN ZONE"X'.&'A".ZONE'7C,AREAS DETERMINED TO BE LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> OU79DE THE 0.21<ANNUAL CHANCE FLOODPWN.ZONE'A' AREAS BJFC`I`TO OF WAY,-RESTRICTIONS OF RECORD WHICH <br /> INUNDATION NED BY THE IX ANNUAALg1ANCE FLOOD�EVENT.THE SURVEYOR MAY AFFECT THE TITLE OR USE OF THE LAND. <br /> MAKES NO E LOCAL <br /> F. M. TO THE ABOVE INFORMATION. PLEASE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> CONTACT THE LOCAL F.EM.A.AGENT FOR VERIFICATION. <br /> BEARING BASIS: LOCATED EXCEPT AS SHOWN. <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERLINE OF DAME 3. NOT VALID WITHOUT THE AUTHENTIC <br /> RAY DRIVE BEING NDD'3W52'E,PER PLAT. ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> ELECTRONIC SEAL OF A FLORIDA LICENSED <br /> REVISED: A M E R I CAN SURVEYOR AND MAPPERIlyslgnedbyJa—W <br /> (FIELD DATE:) S U R V E Y I N G Boleman <br /> µi.s„e0( ON,c=US,st=Flodda,l=0dando, <br /> SCALE: 1' 30 FEET >':'.^")'oq'e -American Surveying&Mapping, <br /> $c M AP P I N G INC- �., ou=Amedcan5urveying& <br /> APPROVED BY: `mil Mapping,cn=James W Boleman, <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB$6393 "m;.•`,+ email=Jbolemanpasmcorpomte.co FOR190901 LOT 35.BLOCK 9 3191 MAGUIRE BOULEVARD, SUITE 200 �::;:•'� m THE <br /> JOB No. ORLANDO. FLORIDA 32803 Location:Orlando,F1 32801 FIRM <br /> (407) 426-7979 Date:2020.03.1707:33:36-0P00' <br /> DRAWN BY. RMB PLAN 03-18-2020 JSO WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM 6485 DATE <br /> PLOT <br />
The URL can be used to link to this page
Your browser does not support the video tag.