My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-22785
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-22785
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/15/2021 10:15:07 AM
Creation date
6/15/2021 10:15:07 AM
Metadata
Fields
Template:
Building Department
Company Name
ZEPHYR LAKES
Building Department - Doc Type
Permit
Permit #
20-22785
Building Department - Name
DR HORTON INC
Address
7752 BROAD POINTE DR
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PLOT PLAN <br /> DESCRIPTION:(AS FURNISHED) <br /> LOT 34, BLOCK 8, ZEPHYR LAKES SUBDIVISION PHASES 1A, 2A, 2B, AND 4A <br /> AS RECORDED IN PLAT BOOK 80, PAGE(S) 37-48, OF THE PUBLIC RECORDS OF PASCO COUNTY, FLORIDA. <br /> PI <br /> Une Table <br /> Line/ Direction Length <br /> I�} L1 NOO'3V52-E 40.00' <br /> w3 m <br /> :3 n a. <br /> a LOT 33 Z <br /> I BLOCK 8 1" = 30' <br /> wI I GRAPHIC SCALE <br /> 15 30 <br /> G S89'25'08'E 9a0 <br /> 0 25.00' S89'25'08"E 115.39' <br /> p, 0 -- -- I 5' D&AE n <br /> IX <br /> 34.3' <br /> Z•ia 34.T" 38.4' aw <br /> 8 0': <br /> O " <br /> a Q I _ _•,. I , .15.3' PROPOSED 2260 < �I*w N O a cn In <br /> �D <br /> p 'w _:C'.':.';:r`" ': COVERED FINISHED FLOOR io � r') y'� O za <br /> Q wo a u - Ug� <br /> O'ENTRY ELEVATION-96,50 I- U O <br /> :o. 00 <br /> 17 Qua <br /> m � l..Yl;. 50.00' a': COwa O �> <br /> mom ' '8.0". N a <br /> C7 In •)27.D'.. 50.0a d 38.4'. <br /> 5'D&AE 01 <br /> m� � N89'25'08"W 115.45� <br /> o . <br /> MCI °" z 3 <br /> I I LOT 35 <br /> BLOCK 8 i 00 rn <br /> O <br /> O <br /> O <br /> 1n <br /> PI <br /> PLAT BOUNDARY <br /> ON LOT CALCULATIONS <br /> LOT = 4,617 SQ. FT. <br /> LIVING AREA = 907 SQ. FT. <br /> GARAGE = 453 SQ' FT. <br /> ENTRY = 64 S0. FT. <br /> LANAI = 0 S0. FT. <br /> PATIO = 80 S0. FT. <br /> DRIVEWAY m 432 SQ. FT. <br /> A/C PAD = 12 SQ. FT. <br /> WALKWAY = 65 SO. FT. <br /> IMPERVIOUS = 44% <br /> = 2013 SO. FT. <br /> PREPARED FOR: SOD = 2,604 ' SO. FT. <br /> OFF LOT CALCULATIONS <br /> D'[tlli01i1[)N� RIGHT OF WAY = 480 SQ. FT. <br /> gSC�dC63�S tdt�Gt'€ DRIVE APRON = 133 S . FT. <br /> PUBLIC S/W = 200 SO. FT. <br /> SOD = 147 SO. FT. <br /> BUILDING SETBACKS TOTALS <br /> AREA = 5,097 S0. FT. <br /> FRONT: 20 DRIVEWAY 565 SQ. FT. <br /> GARAGE: 25' SIDEWALK = 265 SQ. FT. <br /> REAR: 15' <br /> SIDE: 5' SOD = 2,751 SO. FT. <br /> SIDE STREET: 15' <br /> NOTES: LEGEND: <br /> 1. PROPOSED ELEVATIONS SHOWN HEREON ARE —• — — BUILDING SETBACK LINE PI POINT OF INTERSECTION <br /> BASED ON THE APPROVED ENGINEERING PLANS PC POINT OF CURVATURE <br /> PREPARED BY HAMILTON ENGINEERING & —— — CENTERUNE PT POINT OF TANGENCY <br /> SURVEYING INC.. —- -— RIGHT OF WAY LINE RP RADIUS POINT <br /> PRC POINT OF REVERSE CURVATURE <br /> 2. ELEVATIONS ARE BASED ON NAVD 1988 PROPOSED ELEVATION PCP PERMANENT CONTROL POINT <br /> 'DATUM. T!P TYPICAL <br /> PROPOSED DRAINAGE FLOW CS CONCRETE SLAB <br /> THIS PLOT PLAN IS INTENDED FOR PERMITTING PURPOSES CONCRETE �p� CALCULLAATED <br /> ER PT <br /> ONLY. THIS IS NOT INTENDED FOR THE CONSTRUCTION OF PB PLAT BOOK <br /> THE PROPOSED STRUCTURE. THE CONTRACTOR AND/OR A/C AIR CONDITIONER PGS PAGES <br /> OWNER ARE REQUIRED TO VERIFY ALL SETBACKS, BUILDING S/W SIDEWALK SO. FT. SQUARE FEET <br /> DIMENSIONS, AND LAYOUT SHOWN HEREON PRIOR TO ANY F.E.M.A. FEDERAL EMERGENCY MANAGEMENT AGENCY <br /> CONSTRUCTION. F.I.R.M. FLOOD INSURANCE-RATE-MAP-= <br /> NAVD NORTH AMERICAN VERTICAL DATUM <br /> D&UE DRAINAGE&UTILITY EASEMENT <br /> THIS IS NOT A SURVEY DE DRAINAGE EASEMENT UTILITY EASEMENT(PUBLIC) <br /> THIS IS A PLOT PLAN ONLY D&AE DRAINAGE&ACCESS EASEMENT <br /> FLOOD NOTE: SURVEYOR NOTES: <br /> I HAVE EXAMINED THE F.I.R.M. MAP NO. 12101CO293F, 1. THE SURVEYOR HAS NOT ABSTRACTED THE <br /> DATED 09/26/2014, AND FOUND THE SUBJECT PROPERTY LAND SHOWN HEREON FOR EASEMENTS, RIGHT <br /> APPEARS TO UE IN ZONE 'X', AREAS DETERMINED TO BE OF WAY, RESTRICTIONS OF RECORD WHICH <br /> OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN. THE MAY AFFECT THE TITLE OR USE OF THE LAND, <br /> SURVEYOR MAKES NO GUARANTEES AS TO THE ABOVE 2. NO UNDERGROUND IMPROVEMENTS HAVE BEEN <br /> INFORMATION. PLEASE CONTACT THE LOCAL F.E.M.A. <br /> AGENT FOR VERIFICATION. LOCATED EXCEPT AS SHOWN. <br /> BEARING BASIS: A!5hA 3. NOT VAUD WITHOUT THE AUTHENTIC <br /> BEARINGS SHOWN HEREON ARE BASED ON THE CENTERUNE OF BROAD ELECTRONIC SIGNATURE AND THE AUTHENTIC <br /> POINTE DRIVE BEING SDO34'52'W PER PLAT A M E R 1 CA N ELECTRONIC SEAL OF A FLORIDA LICENSED <br /> (FIELD DATE:) REVISED: SURVEYOR AND MAPPER. <br /> SCALE: 1* 30 FEET S U RV EY I N G p°�,xr Digitallysigned by lames W.Boleman <br /> as, <br /> Sc MAPPING INC. DN:cn=James W.Boleman, <br /> j""� �' o=American surveying&Mapping, <br /> APPROVED BY: '� R, _'emaau=HB, <br /> CERTIFICATION OF AUTHORIZATION NUMBER LB/6393 4e email=laoleman@asmmrpomte.com,FOR <br /> 190901 LOT 34, BLOCK 8 3191 MAGUIRE BOULEVARD, SUITE 2DO °m: +`° -"c=us THE <br /> JOB NO. ORLANDO, FLORIDA 32803 ''^_%1 Date:3019.091411:1358-04'00' FIRM <br /> (407) 426-7979 <br /> DRAWN BY' DSB PLOT PLAN 09-20-19 JSO WWW.AMERICANSURVEYINGANDMAPPING.COM JAMES W. BOLEMAN PSM# 6485 DATE <br />
The URL can be used to link to this page
Your browser does not support the video tag.