Laserfiche WebLink
2' HORIZONTAL 2' HORIZONTAL <br /> CLEARANCE CLEARANCE <br /> go so <br /> (MIN.) <br /> z <br /> CLEF,"'Axll?, DONE 6 <br /> SIDEWALK WIDTH ul <br /> > <br /> GRADE <br /> SIDEWALK <br /> SIDEWALK CLEAR ZONE SECTION <br /> NOTES- NTS <br /> 1. THIS CLEAR ZONE APPLIES TO THE SIDEWALK ONLY IT IS NOT INTENDED FOR ROADWAY PLACEMENT SET BACKS. 7 <br /> 2- THE SIDEWALK CLEAR ZONE SHALL BE AN OPEN WINDOW FREE OF OBSTACLES. THIS INCLUDES SHRUBS, TREES, FENCES, ABOVE GROUND c <br /> UTIUTIES, I.E., POWER POLES, STREET LIGHTS, GUY ANCHORS, FIRE HYDRANTS, BLOW—OFFS, MAIL BOXES, STREET SIGNS, UTILITY MARKERS, ETC. <br /> 3. THE SIDEWALK HORIZONTAL CLEAR ZONE CLEARANCE IS MEASURED FROM THE SIDEWALK EDGE AND SHALL BE A MINIMUM OF 2 FEET. <br /> 4. THE SIDEWALK VERTICAL CLEAR ZONE CLEARANCE IS MEASURED FROM THE FINISHED SIDEWALK SURFACE AND SHALL BE A MINIMUM OF 8 FEET. <br /> NOTE: <br /> NO DEVIATIONS TO THIS DETAIL WILL BE PERMITTED UNLESS APPROVED BY THE COUNTY ENGINEER. <br /> ANY PROPOSED ALTERATIONS SHALL BE CLEARLY IDENTIFIED AND HIGHLIGHTED ON DETAIL <br /> PASCO COUNTY Sheet No. <br /> ENGINEERING SERVICES SIDEWALK CLEAR ZONE I of 1 18 <br /> Index No. <br /> DESIGN STANDARDS APPROVED BY Jcw -FBC-C APPROVAL 106 <br /> I REVISED I <br />