Laserfiche WebLink
® , ® <br /> or- <br /> IN LGuIfCoz <br /> SUPPLY & MANUFACTURING <br /> GULF f� <br /> • GUAGE GULFRIBTm PANEL OVER • • <br /> N, FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 <br /> TM <br /> ENGINEER LOAD TABLE:26 Ga. GulfRibTM Panel over 15/32"Plywood <br /> -Buildings having,_a Roof Mean Height<..20'-0",;.,Roofi,Slope;,2- /,1271- 12'/12,;Gab.le or,Hip Roof;Wind:Speeds 120,-, <br /> 180,mp�, Exposure.-IC, Risk Category.II, Endosed.,Building„based;;on F1orida,13ui1ding,,Code,2017.... <br /> 120 130 140 150 160 170 180 <br /> WIIND FASTENER SUBSTRATE <br /> (MIN.1/4" <br /> SPEED penetration) (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> SPACING SPACING SPACING SPACING SPACING SPACING SPACING <br /> ;ZONE 1 #9715x1.5" Plywood,,,, 24",TYPE 1 -24",-TYPE 1, 24 ;TYPE 1, ,24";.-TYPE 1. 24";TYPE 1 :24",TYPE;1 24`',TYPE 1 <br /> ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 2 <br /> ZONE 3 #9-15xts Plywood 24",TYPE 1 24",TYPE.1 -24',TYPE 1 .12",TYPE Z 12 TYPE 2 12",TYPE 2` 12",'TYPE 2 <br /> 1.)PANEL DESCRIPTION: GULFRIBTM, MIN. 26 GA., GRADE 80,36"COVERAGE, 3/4"TALL. <br /> 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL <br /> 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 <br /> PSF @ 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. <br /> 4.) PLYWOOD DECKING: MIN.15/e2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. <br /> 6j LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING <br /> CODE 2017. <br /> ZONE2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> ZONE 3 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> J --—————————————— a less than either 4%of the minimum width of the building or 3 feet. <br /> TYPE 1 FASTENER PATTERN <br /> RIDGE p <br /> At Panel La <br /> I <br /> ZONE 1 \\ \\ I L Cont.Tape Seal for use on Slopes less than 3:12 <br /> (1)#9-15 x 1-1/2'w/Sealer Washer @ 24'O.C.Max. <br /> TYPE 2 FASTENER PATTERN <br /> ZONE 2 GABLE ROOF 1aT 6.5° 2.5" 6.5" 7 2.5° 6.5" 2.5"1-6.6' 2.5° <br /> —J— —————————————————is 7 <br /> RIDGE L Cont.Tape Seal for use on Slopes less than 3:1, <br /> - ————— — I (1)#9.15 x 1-1/2'w/Sealer Washer @ 12'O.C.Max. <br /> — ———————————— ,- a <br /> +----------------------+ a <br /> ZONE 1 <br /> I I <br /> -I-- ————————————————- <br /> ` ZONE 3 EAVE <br /> FL#11651.22 R3•OCTOBER 5,2017 <br /> ENGINEERING,KUHN <br />