My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-625
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-625
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 8:04:42 AM
Creation date
2/24/2022 8:04:41 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-625
Building Department - Name
HOOD,GORDON; EDWARD,SHEILA
Address
38624 B AVE
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
10
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Zo ,FLOAMA PkODUCT APP,ROVAP GUIX66�t <br /> P���!e <br /> SUPPLY & MANUFACTURING <br /> G U L F <br /> ■ GUAGE GULFRIB TM PANEL OVER • • <br /> FLORIDA PRODUCT APPROVAL NO. 11651.22 R3 <br /> TM <br /> Compliance Statement: The product as described in this report has demonstrated compliance with the <br /> Florida Building Code 2017, Sections 1504.3.2. <br /> Product Description: GulfRibTM, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, <br /> through fastened roof panel over minimum 15/32" Plywood Decking. Non <br /> Structural application. <br /> Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to <br /> Florida Building Code 2017 Section 1507.4.3. <br /> Paint Finish Optional <br /> Yield Strength: Min. 80.Oksi <br /> Corrosion Resistance: Panel Material shall comply with Florida Building <br /> Code 2017, Section 1507.4.3. <br /> Panel Dimension(s): Thickness: 0.018" Minimum <br /> Width: 36" Coverage <br /> Rib Height: 3/a" Major Rib at 9" O.C. <br /> Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal <br /> 1/4" minimum penetration through plywood. <br /> Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 <br /> Substrate Description: Minimum15/3z" thick, APA Rated plywood over supports at maximum 24" O.C. <br /> Design of plywood and plywood supports are outside the scope of this <br /> evaluation. Must be designed in accordance w/Florida Building Code 2017. <br /> Design Uplift Pressures: Table"A" <br /> Maximum Total Uplift'Deslgn'Pressureh& ,69 25hpsf � t59 2r5�psf R' <br /> Fastener Pattern 9"-9"-9"-91, 6.5"-2.5"-6.5"- <br /> 2.5"6.5"-2.5"-6.5" <br /> :::a: ,7:" __ .."nib <br /> =Fastelaef.Pa'ttefnyS c1Cjr1 .FYf'?wFu s24iR <br /> :OaC44 ,a'12 0�. f <br /> p g .,f <br /> Design Pressure includes a Safety Factor=2.0. <br /> FL#11651.22 R3•OCTOBER 5,2017 <br /> r ■ , ® ■ ■ ® ■ <br /> ENGINEERING,KUHN <br /> 1SUITE 9. BOCA • <br />
The URL can be used to link to this page
Your browser does not support the video tag.