Laserfiche WebLink
a�' �`''' Corr�rnercia:l Fire Alarm Ce,hi:ular &/or IP <br /> C®MMERCIAL FIRE CELLULAR&IP Flare Ala'rrn Co'r�'m'u'nic�aitOrs <br /> Model Ordering & Specifications veriion' AT&T <br /> LTE WIFi Unique Onboard Eledrlcali In Other Power <br /> Network Cell IP Option Labor/Cost-Saver Patngsput Inputs Input Ratings Outputs Output Ratings Supply <br /> Features (option)t <br /> r <br /> SOLE PATH <br /> SLEATEA-FIRE AT&T Yes No No Panel-PoweredTech'y:tt <br /> Input Voltage/Input IN1:9-25VDC Max input OpenCollector0utputsMax <br /> PGM7 <br /> Current:10V=90mA; INIJA12, current 2mAIN2,IN3: , 3Vwhen active,Max25V <br /> 12-25V=71mA, IN3 9.25VDCMaxin ut PGM2, when not active.Max current <br /> 200mA peak currentl.2mA PGM3 24mA@25V <br /> SLE-LTEV-FIRE Verizon Yes No No P 9 <br /> transmissions <br /> DUAL PATH <br /> 2 TelCo jacks for EZ Panel-PoweredTech'y:n OUTI,OUT2:Dry Contact,Form <br /> SLEATEAI-FIRE AT&T Yes Yes Yes FACP Connect;4 IN1:9.25VDC Max <br /> InputVoltage:l0-25VDC: C Relay,30VAC/DC,500mA <br /> Programmable Input Current:162mA IN1,IN2, input current2mA OUT1, Max PGM3:Open Collector <br /> zone inputs;2 Form'C to 100mAst 162 IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Outputs Max 3Vwhen active, <br /> Relay outputs(avoids 300mA peak IN5 9-25VDCMaxinput PGM3 Max25Vwhenactive.Max <br /> SLE•LTEVI-FIRE Verizon Yes Yes Yes regtforsupervision P g currentl.2mA <br /> module transmissions <br /> current24mA@25V <br /> r <br /> SOLE PATH <br /> SLE•LTEA•CFB AT&T Yes No No Parnel•PoweredTech'y:tt <br /> Input Voltage/Input IN1;9-25VDC Max input Open Collector Outputs Max <br /> Current:10V=90mA; IN1,IN2, current 2mA IN2'IN3: PGM1, 3Vwhen active,Max25V <br /> 12-25V=71 mA, IN3 9.25VDC Max in ut PGM2' when not active.Max current <br /> SLE•LTEV•CFB Verizon Yes No No peak eakduring currentl.2mA PGM3 24mA@25V <br /> transmissions <br /> SLE-LTEA•CFB•PS AT&T Yes No No Direct AC-Powered:Input IN1:9-25VDC Max input Open Collector Outputs Max Transformer <br /> Voltage:120VAC nominal IN1,IN2, current 2mAIN2,IN3: PGM2' 3V when active,Max 25V when (TRF12 <br /> Input Current:1 50mA PGM2, <br /> max;maximum charging IN3 4.25VDCM.2Ainput PGM3 notactiv24mAe. mum current 16nsform r) <br /> SLE-LTEV-CFB•PS Verizon Yes No No current:200mA current 1.2mA 24mA@ 25V transformer) <br /> DUAL PATH <br /> 2 TelCo jacks for EZ Panel-Powered Tech'y:n OUTI,OUT2:Dry Contact,Form <br /> SLE-LTEAI-CFB AT&T Yes Yes Yes FACP Connect;4 IN1:9-25VDC Max <br /> InputVoltage:l0-25VDC: C Relay,30VACIDC,SOOmA <br /> Programmable EOLR IN1,IN2, input current OUTt, <br /> Input Current:162mA Max PGMx3OpenVwh when <br /> zone inputs;2 Form C IN3,IN4, IN2,IN3,IN4,IN5: OUT2, <br /> Relay outputs(avoids to 100mAstandby; INS 9-25VDC Max input PGM3 Outputs Max 3Vwhen active, <br /> SLEATEVI•CFB Verizon Yes Yes Yes regt for supervision 300mApeakduring current l.2mA Max25Vwhenactive.Max <br /> module) transmissions current 24mA@ 25V <br /> 2 TelCo jacks for EZ OUTI,OUT2:Dry Contact,Form <br /> SLE-LTEAI-CFBPS AT&T Yes Yes Yes FACP Connect;4 Direct AC-Powered:Input IN1:9-25VDC Max C Relay,30VAC/DC,500mA Transformer <br /> Programmable EOLR Voltage:120VAC nominal IN1,IN2, input current2mA OUT?, Max PGM3:Open Collector (TRF12 <br /> zone inputs;2 Form C Input Current:200mA IN3,IN4, IN2,IN3,IN4,IN5: OUT2, Outputs Max 3Vwhen active, 16VAC,20VA <br /> Relay outputs(avoids max;maximum charging IN5 9-25VDC Max input PGM3 Max 25V when active.Max transformer) <br /> SLE-LTEVI•CFBPS Verizon Yes Yes Yes regt for supervision current:200mA current1.2mA current 24mA@ 25V <br /> module) <br /> ACCESSORIES: <br /> SLE-WIFI-MODULE Optionally connects supported dual path models to FireLink'"Integrated Fire Alarm Control �t.. <br /> Internet via WiFi,eliminating Ethernet cable connection.Requires 7AH batty. Panel w/StarLink Fire LTE Built In L .. <br /> ("See details WI2191) <br /> SLE-ANTEXT75 Optional extended range omni.antenna w/75'cable, I FL-32FACP-LTEV Firewolf 8 Zone 24V Conventional <br /> premium low-loss cable&full mounting hardware&ground fault isolation Commercial Fire Alarm Control Panel with onboard <br /> mounting plate StarLink Fire"Sole Path,Verizon LTE Cellular <br /> SLE-ANTEXT50 As above,with SO'cable Alarm Communicator and Integral menu-driven <br /> kkk LCD annunciator,w/4amp,24V power supply. <br /> SLE-ANTEXT30 As above,with 30'cable Optionally expandable up to 32 points/zones via <br /> commercial addressable,wireless or conventional <br /> TRF12 Optional Plug in AC Transformer,16.SV/20VA(use I fire devices(2 onboard NACs providing up <br /> is subject to local code compliance)t r' r"_ .., to 4A notification power).Locking metal red <br /> 7 enclosure,(surface or flush mount?removable <br /> Free Commercial Fire LTE Tradeup Trifold 16"x17"door w/14.25"x16"base.Houses 16Ah <br /> Brochures/Moilers/Sruffers(A747) battery backup. <br /> StarUnk Firms _ <br /> 333 Bayview Ave.,Amityville,NY 11701 • 1-800-645-9445 • www.napcosecurity.com <br /> Note:Always consult technical manual and/or AHI for compliance requirements for your area/appiliration.Startnk,StarUnk Fire,Frelink Signal Boost,Panel-Powered Technology,Gemini&Gemini Commercial are trademarks of Napco.AT&T,Verizon,LTE,etc are trademarks <br /> of their respective companies.'StarLink offers full data coverage In US from virtually all panel brands reporting in Contact ID or 412.tt For Panel-Powered technology,regulated auxiliary power outputs are required on listed FACP."Add 40mAto input current&Standby Battery <br /> requirement.Where permitted by AHI;requires conduit..For full details an the StarLink tradeup incentive see online under hUp://www.napcosecuriry.com/starlinVstarlink4gupgrade/tPromo subject to change w/o prior notice.LTE Idespan claims are based on those of carriers. <br /> ©NAPCO,NAPCO Security Technologies Inc.(NASDAQ:NSSq A734A 2019.8 <br />