Laserfiche WebLink
DocuSign Envelope ID:2B7D807B-5824-4F28-9BCD-6EE806ACFOFC <br /> '® to, a1800 W Ashton Blvd. <br /> Lehi, UT 84043 <br /> Structural Group <br /> J.Matthew Walsh, PE Kirk M. Nelson, SE Samuel Brown, PE-Civil <br /> Director of Engineering Structural Engineering Structural Engineering <br /> james.walsh@vivintsolar.com kirk.nelson@vivintsolar.com sam.brown@vivintsolar.com <br /> August 21, 2020 <br /> Re: Structural Engineering Services <br /> Wolf Structure <br /> 6111 19th St, Zephyrhills, FL <br /> S-6409941; FL-01 <br /> To Whom It May Concern: <br /> We have reviewed the following information regarding solar panel installation on the roof of the above referenced <br /> structure: <br /> 1. Site Visit by a representative from our office under my supervision identifying specific interior and <br /> exterior site information including the condition of the existing roof system and the size, spacing, and <br /> condition of existing structural framing members. Information gathered during the site visit includes <br /> photographs, sketches, and verification forms. <br /> 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to <br /> the existing roof. <br /> Based on the above information, we have evaluated the structural capacity of the existing roof system to support the <br /> additional loads imposed by the solar panels and have the following comments related to our review and evaluation: <br /> A. Description of Structure: <br /> The existing structure has typical wood framing construction with metal roofing. All wood material utilized for the <br /> roof system is assumed to be Southern Pine#2 or better with standard construction components. The designed <br /> areas of the home consist of the following framing methods: <br /> • Roof Section: Prefabricated trusses at 24"on center. Survey photos indicate that there was free access <br /> to verify the framing size and spacing. <br /> • Roof Section: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access <br /> to verify the framing size and spacing. <br /> • Roof Section: Prefabricated trusses at 24" on center. Survey photos indicate that there was free access <br /> to verify the framing size and spacing. <br /> B. Loading Criteria <br /> 11.66 PSF= Dead Load (roofing/framing) <br /> 3.00 PSF= Dead Load (solar panels/mounting hardware) <br /> 14.66 PSF=Total Dead Load <br /> 20 PSF = Roof Live Load (based on local requirements) <br /> .Wind speed of 145 mph (based on Exposure Category D-the total area subject to wind uplift is calculated for the <br /> Interior, Edge, and Corner Zones of the dwelling.) <br /> C. Solar Panel Anchorage <br /> 1. Installation shall proceed in accordance with the applicable guidelines and recommendations indicated below. <br /> If, during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office <br /> should be notified before proceeding with the installation. <br /> • EcoFasten Solar Installation Manual, which can be found on the EcoFasten Solar website <br /> (www.ecofastensolar.com). <br /> Page 1 of 2 'vnv nsl�'z So I T <br />