Laserfiche WebLink
G61ICoz <br /> SUPPLY & MANUFACTURING <br /> 11M <br /> G U L F F-,&rjL <br /> ' GUAGE GULFRIBTm PANEL OVER • • OVER • • <br /> FLORIDA PRODUCT APPROVAL r J O. 1 1 i„ 1 I.\ <br /> TM <br /> ENGINEER LOAD TABLE: 29 Ga. GulfRibTM Panel over 1x4 Wood Purlins over 15/32" Plywood <br /> Buildings having a.Robf Mean-Height,< 20'-0";.Roof'Slope:,;2.'/12""--12"/.12".Gable:or Hip Roof-Wind Speeds-'120 <br /> 180mph; Exposure C,'Risk Category II; Enclosed,Building based,on Florida-Building'Code,2017., <br /> 120 130 JA 140 150 160 170 180 <br /> WIIND FASTENER <br /> (MIN.1/4" SUBSTRATE <br /> SPEED penetration) ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER <br /> SPACING SPACING SPACING SPACING SPACING SPACING SPACING <br /> 1x4-Wood <br /> ZONE 1 ' =#9 15x9ti 5"i 24",TYPE 1" 24",TYPE 1 247,TYPE 1 24 TYPE 1' .24";TYPE 1 24",TYPE 1;' 24 TYPE)' <br /> Purlins <br /> ZONE 2 #9-15x1.5" 1x4 Wood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 <br /> Purlins <br /> ZONE 3 #9-'15X1.5" 1 p Wns tl 24 ,TYPE 24';TYPE"1 24",TYPE 1, "" <br /> 1 .24",TYPE 1 24 ,TYPE 2 24';sTYPE 3 24 ,TYPE'2` <br /> 1.)PANEL DESCRIPTION:GULFRIBTM, MIN. 29 GA., GRADE 98, 36"COVERAGE, 3/4" TALL. <br /> 2.) PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL <br /> 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE:76.75 PSF @ 24" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, 123.5 <br /> PSF @ 24" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. <br /> 4.) SUBSTRATE: 1X4 WOOD PURLINS OVER MIN.15/32"THICK PLYWOOD.WOOD PURLINS ATTACHED TO PLYWOOD W/MIN.8D X <br /> 2'Y2" RING SHANK NAILS AT 4" O.C. PURLINS AND PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017 <br /> 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. <br /> 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING <br /> CODE 2017. <br /> ZONE 2 HIP ROOF a Note:Dimension(a)is defined as 10%of the minimum width of the building or <br /> ZONE 3 T 40% of the mean height of the roof,whichever is smaller,however,(a)cannot be <br /> ---------------- a less than either 4%of the minimum width of the building or 3 feet. <br /> \ RIDGE i / / TYPE 1 FASTENER PATTERN <br /> x 4 Wood Purlins @ 24"O.C.Attached to Plywood with <br /> (1)8d x 2.5"Ring Shank Nails @ 4"O.C. At Panel Lap' <br /> ZONE <br /> ------------------� <br /> EAVE (1)#9-15 x 1-1/2"w/Sealer Washer Min.15/32"Plywood <br /> 9"-9"-9"-9"Fastener Pattern @ 24"O.C. <br /> ZONE 2 GABLE ROOF TYPE 2 FASTENER PATTERN <br /> --� --ka <br /> — ----------------- <br /> 1 x 4 Wood Purlins @ 12"O.C.Attached to Plywood with <br /> (1)8d x 2.5"Ring Shank Nails @ 4"O.C. <br /> RIDGE �6.5" 2.5"#--6.5" 2.5" <br /> ----- — i <br /> Eja <br /> ----------------------4 a <br /> ZONE 1 (1)#9-15 x 1-1/2"w/Sealer Washer Min.15/32"Plywood <br /> 6.5"-2.5"-6.5"-2.5"-6.5"-2.5"-6.5"Fastener Pattern @ 24"O.C. <br /> ZONE 3 EAVE <br /> FL#11651.25 R3 •OCTOBER 5,2017 <br /> ENGINEERING,KUHN <br />