R R. W Building Consultants, Inc. <br /> B Consulting and Engineering Services for the Building Industry <br /> P.O.sox 234 Vairico,FL 33595 Phone.813.559.9197 <br /> Florida Board of Professional Engineers Certificate ofAuthorization No.9813 <br /> i <br /> / FL-15819.8 <br /> ! { <br /> Product . Sub Category Manufacturer Product Name <br /> Category <br /> Wincore Window Company,LLC. 7700 19 000 Series <br /> 260 Staunton Turnpike Vinyl Double-Hung <br /> Windows Double Hung I <br /> Parkersburg,WV 26104 Window <br /> "Non-Impact" <br /> Scope. This is a Product Evaluation report issued by:R W Building Consultants♦inc.and Lyndon F.Schmidt,P.E.(System ID# <br /> 1998)for Wincore-Window Company,LLC.based on Rule Chapter.No.61G20-3,Method I of the State of Florida:Product. <br /> Approval,Department of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt, P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named <br /> herein. <br /> Limitations <br /> 1. This product has been evaluated and is in compliance w ith the 6th Edition(2017)Florida Building Code-(FBC)structural requirements <br /> excluding the"High Velocity Hurricane.Zone"(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown;on details.Anchor embedment to base material shall be beyond wall dressing <br /> or stucco: <br /> 3. When used in areas requiring wind borne debris protection this product is required to be protected with an impact-resistant covering <br /> that complies with FBC Sections 1609.1.2&.R301.2.1.2. <br /> 4. For 2x stud framing construction,anchodng.of these units shall be the same as that shown.for 2x buck masonryconstruction. <br /> 5. Site conditions that deviate-from the details of drawing FL-15819.8'require further engineering analysis by a licensed.engineer or <br /> registered.architect. <br /> 6.. See drawing FL-15819.8 for size and-design pressure limitations. <br /> Supporting Documents. <br /> 1. Tes4 Report No. Test Standard I Testing Laboratory Signed by <br /> TEL 02801070 AAMAWDMA/101/I:S.2/A440-0.8 Testing Evaluation Lab.,inc, VX'Wright <br /> TEL02801071 AAMA(WDMA/1A1/i.S.2/A440-08 Testing Evaluation Lab.,Inc. V.K.Wright <br /> 2. Drawing No. Prepared by Signed&Sealed by <br /> No.FL-15819.8 RW Building Consultants, Inc.(CA#9813) Lyndon F.Schmidt;.P.E. <br /> 3. Calculations Prepared by Signed_&Sealed by <br /> Anchoring RW Building Consultants, Inc.(CA#9813) Lyndon-F.°Schmidt,P.E. <br /> ASTM E1800 Glass Load Lyndon F.Schmidt,P.E. <br /> 4. Quality Assurance <br /> Certificate of Participation issued by National Accreditation and <br /> Management Institute,certifying that Wincore Window.Company,I.I.C.is <br /> manufacturing products within a quality assurance program that complies <br /> with ISO/iEC 17020 and Guide 53. �¢4i rrrr� <br /> I bn pn R ♦ R <br /> I <br /> aY k , ny <br /> _tOF <br /> �dr <br /> Lyndon F.Schmidt,RE: <br /> FL PE No.43409 <br /> 7/19/2017 <br /> Sheet 1 of 1 <br />