My WebLink
|
Help
|
About
|
Sign Out
Browse
Search
20-680
Zephyrhills
>
Building Department
>
Permits
>
2020
>
20-680
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/24/2022 10:08:01 AM
Creation date
2/24/2022 10:07:54 AM
Metadata
Fields
Template:
Building Department
Building Department - Doc Type
Permit
Permit #
20-680
Building Department - Name
METZLER,JEREMY & SUSANNE
Address
5850 19TH ST
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
R W R W Building Consultants, Inc. <br /> BConsulting and Engineering Services for the Building Industry <br /> C P.O.Box 230 Valrico,FL 33595 Phone 813.659.9197 <br /> Florida Board or Professional Engineers Certificate of Authorization No.9813 <br /> Proditet EvOtation Report / / 816.6 <br /> i <br /> Product <br /> Category Sub Category Manufacturer Product Name <br /> Wincore Window Company,LLC. 7700/9900 Series <br /> Windows Fixed 260 Staunton Turnpike Vinyl Fixed Window <br /> Parkersburg,WV 26104 "Non-Impact" <br /> Scope: This is a Product Evaluation report issued by R W Building Consultants,Inc.and Lyndon F.Schmidt,P.E.(System ID#1998) <br /> for Wincore Window Company,LLC.based on Rule Chapter No.61G20-3,Method 1 D of the State of Florida Product <br /> Approval,Department of Business&Professional Regulation. <br /> RW Building Consultants and Lyndon F.Schmidt,P.E.do not have nor will acquire financial interest in the company <br /> manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. <br /> Limitations: <br /> 1. This product has been evaluated and is in compliance with the 6th Edition(2017)Florida Building Code(FBC)structural requirements <br /> excluding the"High Velocity Hurricane Zone"(HVHZ). <br /> 2. Product anchors shall be as listed and spaced as shown on details.Anchor embedment to base material shall be beyond wall dressing or <br /> stucco. <br /> 3. When used in areas requiring wind borne debris protection this product is required to be protected with an impact resistant covering that <br /> complies with FBC Sections 1609.1.2&R301.2.1.2. <br /> 4. For 2x stud framing construction,anchoring of these units shall be the same as that shown for 2x buck masonry construction. <br /> 5. Site conditions that deviate from the details of drawing FL-15816.E require further engineering analysis by a licensed engineer or <br /> registered architect. <br /> 6. See drawing FLA 5816.6 for size and design pressure limitations. <br /> Supporting Documents: <br /> 1. Test Report No. Test Standard Testing Laboratory Signed by <br /> AT]B6715.02-501-47 AAMA/WDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Lynn George <br /> ATI C6371.02-501-47 AAMA/WDMA/101/I.S.2/A440-08 Architectural Testing,Inc. Lynn George <br /> 2. Miami-Dade NOA Material <br /> 15-1201.11 Saflex® PVB Interlayer(Eastman Chemical Co.) <br /> 3. Drawing No. Prepared by Signed&Sealed by <br /> No.FL-15816.E RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt,P.E. <br /> 4. Calculations Prepared by Signed&Sealed by <br /> Anchoring RW Building Consultants,Inc.(CA#9813) Lyndon F.Schmidt.P.E. <br /> ASTM E 1300 Glass Load Lyndon F.Schmidt,P.E. <br /> 5. Quality Assurance <br /> Certificate of Participation issued by National Accreditation and Management <br /> Institute,certifying that Wincore Window Company,LLC.is manufacturing <br /> products within a quality assurance program that complies with ISO/IEC <br /> 17020 and Guide 53. <br /> �Q;5FtiG49;<<�Pp <br /> f _ <br /> z <br /> gbh r�'l•'!:;;'.'-- <br /> "S�GiiiSc <br /> Lyndon F.Schmidt,P.E. <br /> FL PE No.43409 <br /> Sheet 1 of 1 7/18/2017 <br />
The URL can be used to link to this page
Your browser does not support the video tag.